3 Operation

Operation manual

3

EHYH EHYHBH/X08AA
Daikin Altherma hybrid heat pump
4P349588­1 – 2013.05

c

Instant domestic hot water or domestic hot water (DHW) tank

d

User interface at the indoor unit

e

User interface in the living room, used as room thermostat

f

Radiators

g

Heat pump convectors or fan coil units

3

Operation

3.1

Overview: Operation

You  can  operate  the  system  via  the  user  interface.  This  part
describes how to use the user interface:

Part

Description

At a glance

▪ Buttons

▪ Status icons

Space heating/cooling
control

How to control space heating/cooling:

▪ Setting the space operation mode

▪ Controlling the temperature

Domestic hot water
control

How to control domestic hot water:

▪ Reheat mode

▪ Scheduled mode

▪ Sch reheat mode

Schedules

How to select and program schedules.

Menu structure

Overview of menu structure

Installer settings table

Overview of installer settings

3.2

The user interface at a glance

3.2.1

Buttons

a

e

f

b

d

c

a

 HOME PAGES

▪ Switches  between  home  pages  (when  you  are  on  a  home

page).

▪ Goes  to  the  default  home  page  (when  you  are  in  the  menu

structure).

b

 MALFUNCTION INFORMATION

If  a  malfunction  occurs, 

  is  displayed  on  the  home  pages.

Press 

 to display more information about the malfunction.

c

 ON/OFF

Turns  ON  or  OFF  one  of  the  controls  (room  temperature,
leaving water temperature, DHW tank temperature).

d

 MENU STRUCTURE/BACK

▪ Opens the menu structure (when you are on a home page).
▪ Goes up a level (when you are navigating through the menu

structure).

▪ Goes  back  1  step  (example:  when  you  are  programming  a

schedule in the menu structure).

e

 

 

 

 NAVIGATING/CHANGING SETTINGS

▪ Navigates the cursor on the display.
▪ Navigates through the menu structure.
▪ Changes settings.
▪ Selects a mode.

f

 OK

▪ Confirms a selection.
▪ Enters a submenu in the menu structure.
▪ Switches  between  displaying  actual  and  desired  values,  or

between displaying actual and offset values (if applicable) on
the home pages.

▪ Goes  to  the  next  step  (when  you  are  programming  a

schedule in the menu structure).

▪ Enables you to activate or deactivate child lock if pressed for

more than 5 seconds on a home page.

▪ Enables  you  to  activate  or  deactivate  a  function  lock  if

pressed  for  more  than  5  seconds  in  the  main  menu  of  the
menu structure.

INFORMATION

If you press 

 or 

 while changing settings, the changes

will NOT be applied.

3.2.2

Status icons

Icon

Description

Space operation mode = Heating.

Space operation mode = Cooling.

Heat pump is operating.

Desired room temperature = preset value (Comfort;
daytime).

Desired room temperature = preset value (Eco;
nighttime).

▪ On  the  room  temperature  home  page:  Desired

room  temperature  =  according  to  the  selected
schedule.

▪ On  the  DHW  tank  temperature  home  page:

DHW tank mode = Scheduled mode.

DHW tank mode = Reheat mode.

 

DHW tank mode = Sch reheat mode.

At the next scheduled action, the desired temperature
will increase.

At the next scheduled action, the desired temperature
will NOT change.

At the next scheduled action, the desired temperature
will decrease.

The preset value (Comfort or Eco) or scheduled value
is temporarily overruled.

The system will produce domestic hot water for the
indicated number of persons.

The DHW tank booster mode is active or ready to be
activated.

Quiet mode is active.

Holiday mode is active or ready to be activated.

Child lock mode and/or function lock mode is active.

Summary of Contents for EHYHBH05AA

Page 1: ...Operation manual Daikin Altherma hybrid heat pump English Operation manual Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA ...

Page 2: ...ance Request the installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a documentation set The complete set consists of Document Contains Format General safety precautions Safe...

Page 3: ... the menu structure e NAVIGATING CHANGING SETTINGS Navigates the cursor on the display Navigates through the menu structure Changes settings Selects a mode f OK Confirms a selection Enters a submenu in the menu structure Switches between displaying actual and desired values or between displaying actual and offset values if applicable on the home pages Goes to the next step when you are programming...

Page 4: ... between home pages go to User settings Display User profile User profile Basic User profile Detailed 20 0 C 1 5 2 0 A c t u a l t e m p e r a t u r e Mon Room 20 0 C 1 5 2 0 1 7 3 0 A c t u a l t e m p e r a t u r e Scheduled Tue Mon Room To read out the actual and desired room temperature 1 Go to the room temperature home page Room Result You can read out the actual temperature 20 0 C A c t u a ...

Page 5: ...ent and long space heating cooling interruptions will happen Scheduled mode In scheduled mode the DHW tank produces hot water corresponding to a schedule The best time to allow the tank to produce hot water is at night because The space heating demand is lower Electricity tariffs are lower Example t 60 C 00 00 07 00 50 C 15 C 40 C 14 00 21 00 1 2 3 4 5 Tt Tt DHW tank temperature t Time Scheduled r...

Page 6: ... 5 1 To program the schedule 1 Go to 7 3 1 1 User settings Set schedules Room temp Set heating schedule 2 Select Empty and press 3 Program the schedule for Monday See below for more details 4 Copy from Monday to Tuesday Wednesday Thursday and Friday See below for more details 5 Program the schedule for Saturday 6 Copy from Saturday to Sunday 7 Save the schedule and give it a name See below for mor...

Page 7: ...ation 6 Display Temperature lock Set schedules Preset values User settings 7 Allowed operation mode Unit of measurement Holiday Holiday mode From Until Holiday 2 Operation mode Away Heating Cooling Consumed elec Produced energy Energy metering 6 2 Error history Contact helpdesk number Error information 6 3 Contrast Backlit LCD time User profile Available home pages Display 7 1 Room temperature LWT...

Page 8: ...on A 3 1 1 5 Modulated LWT 0 No Leaving water temperature Emitter type A 3 1 1 7 Emitter type 1 Slow Savings mode A 6 7 Savings mode 0 Economical Setting Default Fill in Fuel price 7 4 6 Fuel price 8 0 kWh Electricity price 7 4 5 Elec price 20 kWh High 20 kWh Medium 15 kWh Low 3 7 3 Domestic hot water control A 4 Setting Default Fill in Type 2 Scheduled only Setpoint readout type 0 Temperature Max...

Page 9: ...kly schedule for your normal space heating or cooling needs If necessary you can easily deviate from the schedule For shorter periods You can overrule the scheduled room temperature Example When you have a party or when you are leaving for a couple of hours For longer periods You can use the holiday mode Example When you stay at home during your holiday or when you go away during your holiday Tips...

Page 10: ...f the problems recurs daily do one of the following Increase the DHW tank temperature preset value Adjust the DHW tank temperature schedule Example Program to additionally heat up the DHW tank to a preset value Storage eco lower tank temperature during the day The desired DHW tank temperature is too low The instant DHW temperature is too low Only applicable when no tank is installed Increase the i...

Page 11: ......

Page 12: ...4P349588 1 2013 05 Copyright 2013 Daikin ...

Reviews: