background image

 

Operation manual

 

3

 

EKHBH/X008BA

 

Indoor unit for air to water heat pump system and options

 

4PW54184-1

 

O

 

PERATING

 

 

 

THE

 

 

 

DIGITAL

 

 

 

CONTROLLER

 

Operating the EKHB* unit comes down to operating the digital
controller.

 

Features and functions

 

The digital controller is a state of the art controller that offers full
control over your installation. It can control a heating/cooling and a
heating only installation.

Both installations are available in multiple versions which vary in
capacity, electrical supply and installed equipment (with an optional
domestic hot water tank with a booster heater).

 

Basic controller functions

 

The basic controller functions are:

 

 

Turning the unit ON/OFF.

 

 

Operation mode change-over:
-

space heating (refer to 

page 5

),

-

space cooling (refer to 

page 5

) (*),

-

domestic water heating (refer to 

page 5

) (*).

 

 

Selection of features:
-

quiet mode (refer to 

page 5

),

-

weather dependent control (refer to 

page 6

).

 

 

Temperature set point adjustment (refer to 

page 5

).

The digital controller supports a power cut off of maximum 2 hours.
When autorestart is enabled (see 

"Field settings" on page 10

) this

allows a power supply shut down of 2 hours without user intervention
(e.g. benefit kWh rate power supply).

 

Clock function

 

The clock functions are:

 

 

24 hour real time clock.

 

 

Day of the week indicator.

 

Schedule timer function

 

The schedule timer function allows the user to schedule the
operation of the installation according to a daily or a weekly program.

 

Name and function of buttons and icons

 

1.

 

HEATING/COOLING ON/OFF BUTTON 

 

y

 

The ON/OFF button starts or stops the heating or cooling
function of the unit.

When the unit is connected with an external room thermostat,
this button is not operable and the icon 

 

e

 

 is shown.

Pressing the ON/OFF button consecutively too many times may
cause malfunction of the system (maximum 20 times per hour).

 

2.

 

OPERATION LED 

 

0

 

The operation LED is lit during space heating or space cooling
operation. The LED blinks if a malfunction occurs. When the
LED is OFF, space heating or space cooling are inactive while
the other operation modes can still be active.

 

3.

 

OPERATION MODE ICONS 

 

hcws

 

These icons indicate the current operation mode(s): space
heating (

 

h

 

), space cooling (

 

c

 

), domestic water heating (

 

w

 

) or

quiet mode (

 

s

 

). Within limits, different modes can be combined,

e.g. space heating and domestic water heating. The
corresponding mode icons will be displayed simultaneously.

In a heating only installation, the 

 

c

 

 icon will never be displayed.

If the domestic hot water tank is not installed, the 

 

w

 

  icon will

never be displayed.

If the solar option is installed and active, the 

 

w

 

  icon will be

blinking.

 

4.

 

EXTERNAL CONTROL ICON 

 

e

 

This icon indicates that the room thermostat (optional) with
higher priority is controlling your installation. This external room
thermostat can start and stop the space heating/cooling
operation and change the operation mode (heating/cooling).

When the external room thermostat with a higher priority is
connected, the schedule timer for space heating and space
cooling will not function.

When the benefit kWh power rate signal is sent, the centralised
control indication 

 

e

 

 will flash to indicate that benefit kWh power

rate is active.

 

5.

 

DAY OF THE WEEK INDICATOR 

 

1234567

 

This indicator shows the current weekday.

When reading or programming the schedule timer, the indicator
shows the set day.

 

6.

 

CLOCK DISPLAY 

 

8

 

The clock display shows the current time.

When reading or programming the schedule timer, the clock
display shows the action time.

 

CAUTION

 

Never let the digital controller get wet. This may cause an
electric shock or fire.

Never press the buttons of the digital controller with a hard,
pointed object. This may damage the digital controller.

Never inspect or service the digital controller yourself, ask
a qualified service person to do this.

 

 

Descriptions in this manual that apply to a specific
installation or that depend on the installed equipment,
are marked with an asterisk (*).

 

 

Some functions described in this manual may not be
available or should not be available. Ask your installer
or your local dealer for more information on
permission levels.

 

(*) The functions 'space cooling' and 'domestic water
heating' can only be selected when the corresponding
equipment is installed.

 

Remark that pushing the 

 

y

 

  button has no influence on

the domestic water heating. Domestic water heating is only
switched on or off by means of the 

 

v

 

 button.

1

17

3

5

6

24

8

13

25

26

11

19

21

14

4

7

9

12
10

22

34

27

28

23

20

33

32

31

29

30

2

16

18

15

Summary of Contents for EKHBH008BA

Page 1: ...OPERATION MANUAL EKHBH008BA EKHBX008BA Indoor unit for air to water heat pump system and options...

Page 2: ...water ERHQ or ERLQ heat pumps These units are designed for wall mounted indoor installation The units can be combined with Daikin fan coil units floor heating applications low temperature radiators D...

Page 3: ...stat connected to the indoor unit This will prevent excessive space heating and will stop the outdoor unit and the indoor circulation pump when the room temperature is above the thermostat set point N...

Page 4: ...eration mode s space heating h space cooling c domestic water heating w or quiet mode s Within limits different modes can be combined e g space heating and domestic water heating The corresponding mod...

Page 5: ...E HEATING COOLING BUTTON This button allows manual switching between heating or cooling mode provided the unit is not a heating only unit When the unit is connected with an external room thermostat th...

Page 6: ...ater provides auxiliary heating for the domestic hot water tank Powerful domestic water heating operation In the case of urgent need of domestic hot water the domestic hot water temperature set point...

Page 7: ...R refer to chapter Programming and consulting the schedule timer on page 7 What can the schedule timer do The schedule timer allows the programming of 1 Space heating and space cooling refer to Progra...

Page 8: ...in a chronological way start with action 1 for the first action and end with the highest number for the last action This is not a requirement but will simplify the interpretation of the program later...

Page 9: ...to select x to switch cooling or heating and the controller off 9 set the temperature by means of the bi and bj buttons a to select automatic temperature calculation only in heating mode 10 Use the pi...

Page 10: ...you want to consult 2 Press the button The actual mode is blinking 3 Press the button to confirm the selected mode The actual day is blinking 4 Select the day you would like to consult by means of the...

Page 11: ...ode cooling or heating you want to delete 2 Press the button The actual mode is blinking 3 Press the button to confirm the selected mode The actual day is blinking 4 Select the day you would like to d...

Page 12: ...tallations with a domestic hot water tank The disinfection function disinfects the domestic hot water tank by periodically heating the domestic hot water to a specific temperature 2 00 Operation inter...

Page 13: ...Local shift value weather dependent Local shift value weather dependent The local shift value weather dependent field setting is only relevant in case weather dependent set point see field setting 1 W...

Page 14: ...restart 00 Status 0 ON 0 1 4 Space heating off temperature 00 Installation related setting 01 Installation related setting 02 Space heating off temperature 25 14 25 1 C 03 Installation related setting...

Page 15: ...related setting D Local shift value weather dependent 00 Installation related setting 01 Installation related setting 02 Installation related setting 03 Local shift value weather dependent 0 0 1 2 3...

Page 16: ...ed household waste Do not try to dismantle the system yourself the dismantling of the system treatment of the refrigerant of oil and other parts must be done by a qualified installer in accordance wit...

Page 17: ......

Page 18: ...4PW54184 1 Copyright Daikin...