background image

 

Operation manual

 

1

 

EKHBH/X008BA

 

Indoor unit for air to water heat pump system and options

 

4PW54184-1

 

C

 

ONTENTS

 

Page

 

Introduction ..................................................................................... 1

 

This manual ............................................................................................... 1
General information ................................................................................... 1
Safety considerations ................................................................................ 2

 

Operating the unit ........................................................................... 2

 

Introduction ....................................................................................... 2

Operating the digital controller .......................................................... 3

 

Features and functions .............................................................................. 3

Basic controller functions ...................................................................... 3
Clock function........................................................................................ 3
Schedule timer function......................................................................... 3

Name and function of buttons and icons ................................................... 3
Setting up the controller............................................................................. 5

Setting the clock .................................................................................... 5
Setting the schedule timer..................................................................... 5

Description of the operation modes ........................................................... 5

Space heating operation (

 

h

 

) ................................................................. 5

Space cooling operation (

 

c

 

) ................................................................. 5

Domestic water heating operation (

 

w

 

) ................................................. 5

Quiet mode operation (

 

s

 

).................................................................... 5

Controller operations ................................................................................. 5

Manual operation................................................................................... 5
Schedule timer operation ...................................................................... 6

Programming and consulting the schedule timer....................................... 7

Getting started....................................................................................... 7
Programming......................................................................................... 8
Consulting programmed actions............................................................ 9
Tips and tricks ..................................................................................... 10

 

Field settings ................................................................................... 10

 

Procedure ................................................................................................ 10
Detailed description ................................................................................. 11
Field settings table................................................................................... 13

 

Maintenance .................................................................................. 15

 

Important information regarding the refrigerant used .............................. 15
Maintenance activities ............................................................................. 15
Standstill .................................................................................................. 15

 

Troubleshooting ............................................................................ 15

Disposal requirements ................................................................. 15

 

The English text is the original instruction. Other languages are
translations of the original instructions.

This appliance is not intended for use by persons, including children,
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with
the appliance.

 

I

 

NTRODUCTION

 

This manual

 

This manual describes how to start up and switch off the unit, set
parameters and configure the schedule timer by means of the
controller, maintain the unit and solve operational problems.

 

General information

 

Thank you for purchasing this indoor unit.

The unit is the indoor part of the air to water ERHQ or ERLQ heat
pumps. These units are designed for wall mounted indoor installation.
The units can be combined with Daikin fan coil units, floor heating
applications, low temperature radiators, Daikin domestic water
heating applications and Daikin solar kit for domestic hot water
applications.

 

Heating/cooling units and heating only units

 

The unit range consists of two main versions: a heating/cooling
(EKHBX) version and a heating only (EKHBH) version.

Both versions are delivered with an integrated backup heater for
additional heating capacity during cold outdoor temperatures. The
backup heater also serves as a backup in case of malfunctioning of
the outdoor unit. The backup heater models are available for a
heating capacity of 3, 6 and 9 kW, and – depending on the heating
capacity – for three different power supply specifications.

 

Domestic hot water tank (option)

 

An optional EKHW* domestic hot water tank with integrated 3 kW
electrical booster heater can be connected to the indoor unit. The
domestic hot water tank is available in three sizes: 150, 200 and
300 litre.

 

Solar kit for domestic hot water tank (option)

 

For information concerning the EKSOLHW solar kit, refer to the
installation manual of that kit.

 

Remote thermostat kit (option)

 

An optional room thermostat EKRTW, EKRTWA, or EKRTR can be
connected to the indoor unit. Refer to the operation manual of the
room thermostat for more information.

 

EKHBH008BA***
EKHBX008BA***

 

Indoor unit for air to water heat pump system

and options

 

Operation manual

 

READ THIS MANUAL ATTENTIVELY BEFORE STARTING
UP THE UNIT. DO NOT THROW IT AWAY. KEEP IT IN
YOUR FILES FOR FUTURE REFERENCE.

 

Before operating the unit, make sure the installation has
been carried out correctly by a professional Daikin dealer.

If you feel unsure about operation, contact your Daikin
dealer for advice and information.

 

Indoor unit model

Backup heater capacity

Backup heater 

nominal voltage

EKHB*008BA3V3

 

3 kW

1x 230 V

 

EKHB*008BA6V3

 

6 kW

1x 230 V

 

EKHB*008BA6WN

 

6 kW

3x 400 V

 

EKHB*008BA9WN

 

9 kW

3x 400 V

 

EKHB*008BA6T1

 

6 kW

3x 230 V

 

EKHB*008BA9T1

 

9 kW

3x 230 V

Summary of Contents for EKHBH008BA

Page 1: ...OPERATION MANUAL EKHBH008BA EKHBX008BA Indoor unit for air to water heat pump system and options...

Page 2: ...water ERHQ or ERLQ heat pumps These units are designed for wall mounted indoor installation The units can be combined with Daikin fan coil units floor heating applications low temperature radiators D...

Page 3: ...stat connected to the indoor unit This will prevent excessive space heating and will stop the outdoor unit and the indoor circulation pump when the room temperature is above the thermostat set point N...

Page 4: ...eration mode s space heating h space cooling c domestic water heating w or quiet mode s Within limits different modes can be combined e g space heating and domestic water heating The corresponding mod...

Page 5: ...E HEATING COOLING BUTTON This button allows manual switching between heating or cooling mode provided the unit is not a heating only unit When the unit is connected with an external room thermostat th...

Page 6: ...ater provides auxiliary heating for the domestic hot water tank Powerful domestic water heating operation In the case of urgent need of domestic hot water the domestic hot water temperature set point...

Page 7: ...R refer to chapter Programming and consulting the schedule timer on page 7 What can the schedule timer do The schedule timer allows the programming of 1 Space heating and space cooling refer to Progra...

Page 8: ...in a chronological way start with action 1 for the first action and end with the highest number for the last action This is not a requirement but will simplify the interpretation of the program later...

Page 9: ...to select x to switch cooling or heating and the controller off 9 set the temperature by means of the bi and bj buttons a to select automatic temperature calculation only in heating mode 10 Use the pi...

Page 10: ...you want to consult 2 Press the button The actual mode is blinking 3 Press the button to confirm the selected mode The actual day is blinking 4 Select the day you would like to consult by means of the...

Page 11: ...ode cooling or heating you want to delete 2 Press the button The actual mode is blinking 3 Press the button to confirm the selected mode The actual day is blinking 4 Select the day you would like to d...

Page 12: ...tallations with a domestic hot water tank The disinfection function disinfects the domestic hot water tank by periodically heating the domestic hot water to a specific temperature 2 00 Operation inter...

Page 13: ...Local shift value weather dependent Local shift value weather dependent The local shift value weather dependent field setting is only relevant in case weather dependent set point see field setting 1 W...

Page 14: ...restart 00 Status 0 ON 0 1 4 Space heating off temperature 00 Installation related setting 01 Installation related setting 02 Space heating off temperature 25 14 25 1 C 03 Installation related setting...

Page 15: ...related setting D Local shift value weather dependent 00 Installation related setting 01 Installation related setting 02 Installation related setting 03 Local shift value weather dependent 0 0 1 2 3...

Page 16: ...ed household waste Do not try to dismantle the system yourself the dismantling of the system treatment of the refrigerant of oil and other parts must be done by a qualified installer in accordance wit...

Page 17: ......

Page 18: ...4PW54184 1 Copyright Daikin...

Reviews: