EKHBH/X008BB
Indoor unit for air to water heat pump system
4PW62570-1A – 01.2011
Installation manual
14
6.3.
Inspecting, handling and unpacking the unit
■
The indoor unit is packed in a cardboard box, fixed by straps on
a wooden pallet.
■
At delivery, the unit must be checked and any damage must be
reported immediately to the carrier claims agent.
■
Check if all indoor unit accessories (see
) are enclosed.
■
Bring the unit as close as possible to its final installation position
in its original package in order to prevent damage during
transport.
■
The indoor unit weighs approximately 46 kg and should be lifted
by two persons using the two lifting bars provided.
6.4.
Mounting the indoor unit
1
Put the installation pattern (see packing) on the wall and mark
the fixation positions (2 on top (
●
T) and 2 at the bottom (
●
B)).
Make sure that the marks (2 by 2) are completely level and the
dimensions of the marks are corresponding according to
When the unit is not installed level, air might get trapped in the
water circuit resulting in malfunctioning of the unit.
Pay special attention to this when installing an EKHBX model to
prevent overflow of the drain pan.
2
Drill 4 holes and install 4 plugs (suitable for M10).
3
Put the screws in top plugs and hang the indoor unit on the top
screws.
4
Put the screws in bottom plugs and fix the screws firmly.
CAUTION
■
Do not grasp the switch box or piping to lift the unit!
Two lifting bars are provided to lift the unit.
■
Safely dispose of packing materials. Packing
materials, such as nails and other metal or wooden
parts, may cause stabs or other injuries.
WARNING
Tear apart and throw away plastic packaging bags so that
children will not play with them. Children playing with
plastic bags face danger of death by suffocation.
CAUTION
The weight of the indoor unit is approximately 46 kg. Two
persons are required to mount the unit.
4
2
1
3
1