background image

EKHBH/X016BA

Indoor unit for air to water heat pump system and options

4PW54186-1

Operation manual

10

10

Press the 

<

  button for 5 seconds to store the programmed

actions.

If the 

<

  button is pressed when action number 3 is displayed,

actions 1, 2 and 3 are stored but 4 and 5 are deleted.

You automatically return to step 

4

.  By pressing the 

pr

  button

several times, you return to previous steps in this procedure and
finally return to normal operation.

Consulting programmed actions

Consulting space heating or space cooling actions

Consulting space heating or space cooling is carried out as follows.

1

Use the 

=

  button to select the operation mode (heating or

cooling) you want to consult.

2

Press the 

<

 button.

The actual mode is blinking.

3

Press the 

<

 button to confirm the selected mode.

The actual day is blinking.

4

Select the day you would like to consult by means of the 

pi

and 

pj

 buttons.

The selected day is blinking.

5

Press the 

<

 button to confirm the selected day.

The first programmed action of the selected day appears.

6

Use the 

pi

  and 

pj

  buttons to consult the other

programmed actions of that day.

This is called the readout mode. Empty program actions (e.g. 4
and 5) are not displayed.

By pressing the 

pr

 button several times, you return to previous

steps in this procedure and finally return to normal operation.

Consulting domestic water heating, booster heater or quiet
mode

Consulting domestic water heating, booster heater or quiet mode is
carried out as follows.

1

Press the 

<

 button.

The actual mode is blinking.

2

Use the 

pi

 and 

pj

 buttons to select the mode you want

to consult (quiet mode 

s

, booster heating 

m

  or domestic

water heating 

w

).

The selected mode is blinking.

3

Press the 

<

 button to confirm the selected mode.

The first programmed action is displayed.

4

Use the 

pi

  and 

pj

  buttons to consult the programmed

actions.

This is called the readout mode. Empty program actions (e.g. 4
and 5) are not displayed.

By pressing the 

pr

 button several times, you return to previous

steps in this procedure and finally return to normal operation.

Tips and tricks

Programming the next day(s)

After confirming the programmed actions of a specific day (i.e. after
pressing the 

<

 button for 5 seconds), press the 

pr

 button once. You

can now select another day by using the 

pi

 and 

pj

 buttons

and restart consulting and programming.

Copying programmed actions to next day

In heating/cooling program it is possible to copy all programmed
actions of a specific day to the next day (e.g. copy all programmed
actions from "

1

" to "

2

").

To copy programmed actions to the next day, proceed as follows:

1

Press the 

<

 button.

The actual mode is blinking.

2

Use the 

pi

 and 

pj

 buttons to select the mode you want

to program.

The selected mode is blinking.

You can leave programming by pressing the 

pr

 button.

3

Press the 

<

 button to confirm the selected mode.

The actual day is blinking.

4

Select the day you would like to copy to the next day by means
of the 

pi

 and 

pj

 buttons.

The selected day is blinking.

You can return to step 

2

 by pressing the 

pr

 button.

5

Press the 

<

 and 

pr

 buttons simultaneously for 5 seconds.

After 5 seconds the display will show the next day (e.g. "

2

" if

"

1

" was selected first). This indicates that the day has been

copied.

You can return to step 

2

 by pressing the 

pr

 button.

Deleting one or more programmed actions

Deleting one or more programmed actions is done at the same time
as storing the programmed actions.

When all actions for one day have been programmed, make sure that
the display shows the highest action number you would like to save.
By pressing the 

<

 button for 5 seconds, you store all actions except

those with a higher action number than the one that is displayed.

E.g. when the 

<

  button is pressed when action number 3 is

displayed, actions 1, 2 and 3 are stored but 4 and 5 are deleted.

Deleting a mode

1

Press the 

<

 button.

The actual mode is blinking.

2

Use the 

pi

 and 

pj

 buttons to select the mode you want

to delete (quiet mode 

s

, booster heating 

m

 or domestic water

heating 

w

).

The selected mode is blinking.

3

Press the 

<

  and 

ba

  button simultaneously for 5 seconds to

delete the selected mode.

Deleting a day of the week (heating or cooling mode)

1

Use the 

=

  button to select the operation mode (heating or

cooling) you want to delete.

2

Press the 

<

 button.

The actual mode is blinking.

3

Press the 

<

 button to confirm the selected mode.

The actual day is blinking.

4

Select the day you would like to delete by means of the 

pi

and 

pj

 buttons.

The selected day is blinking.

5

Press the 

<

  and 

ba

  button simultaneously for 5 seconds to

delete the selected day.

Consulting space heating or space cooling is done in the
same way. At the start of the consulting procedure space
heating or space cooling is selected. After that, you have to
return to the start of the consulting procedure to consult
the other operation mode.

Returning to previous steps in this procedure is done by
pressing the 

pr

 button.

Returning to previous steps in this procedure is done by
pressing the 

pr

 button.

Summary of Contents for EKHBH016BA

Page 1: ...OPERATION MANUAL EKHBH016BA EKHBX016BA Indoor unit for air to water heat pump system and options...

Page 2: ...to water ERHQ or ERLQ heat pumps These units are designed for wall mounted indoor installation The units can be combined with Daikin fan coil units floor heating applications low temperature radiators...

Page 3: ...rmostat connected to the indoor unit This will prevent excessive space heating and will stop the outdoor unit and the indoor circulation pump when the room temperature is above the thermostat set poin...

Page 4: ...eration mode s space heating h space cooling c domestic water heating w or quiet mode s Within limits different modes can be combined e g space heating and domestic water heating The corresponding mod...

Page 5: ...E HEATING COOLING BUTTON This button allows manual switching between heating or cooling mode provided the unit is not a heating only unit When the unit is connected with an external room thermostat th...

Page 6: ...turns to space heating operation Space cooling operation c In this mode cooling will be activated as required by the water temperature set point Domestic water heating operation w In this mode the ind...

Page 7: ...n 1 Press v for 5 seconds to activate powerful domestic water heating operation Icons w and m start flashing Powerful domestic water heating is deactivated automatically when the set point for the dom...

Page 8: ...rammed at 13 00 16 00 and 19 00 The last programmed command 16 00 overruled the previous programmed command 13 00 and will remain active until the next programmed command 19 00 occurs So in order to k...

Page 9: ...nt Conversely when programming cooling actions time and set point heating actions are added automatically at the same time but with the default heating set point The set points of these automatically...

Page 10: ...nds to store the programmed actions If the button is pressed when action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted You automatically return to step 6 By pressing the p...

Page 11: ...ram it is possible to copy all programmed actions of a specific day to the next day e g copy all programmed actions from 1 to 2 To copy programmed actions to the next day proceed as follows 1 Press th...

Page 12: ...ep 2 through 4 to change other field settings as required 7 When finished press the z button to exit FIELD SET MODE Detailed description 0 User permission level If required certain user interface butt...

Page 13: ...2 Start time time of the day at which the domestic hot water should be heated 2 03 Set point high water temperature to be reached 2 04 Interval time period defining how long the set point temperature...

Page 14: ...not change this setting Leave it set to its default value C Setup on EKRP1HB digital I O PCB Solar priority mode C 00 Solar priority mode setting for information concerning the EKSOLHW solar kit refe...

Page 15: ...restart 00 Status 0 ON 0 1 4 Space heating off temperature 00 Installation related setting 01 Installation related setting 02 Space heating off temperature 35 14 35 1 C 03 Installation related setting...

Page 16: ...O PCB 00 Solar priority mode setting 0 0 1 1 01 Installation related setting 02 Installation related setting 03 Installation related setting 04 Installation related setting D Local shift value weathe...

Page 17: ...ed household waste Do not try to dismantle the system yourself the dismantling of the system treatment of the refrigerant of oil and other parts must be done by a qualified installer in accordance wit...

Page 18: ...NOTES NOTES...

Page 19: ......

Page 20: ...4PW54186 1 Copyright Daikin...

Reviews: