EKHBH/X030BA
Indoor unit for air to water heat pump system and options
4PW62569-1 – 07.2010
Operation manual
16
9
Cooling and heating set point ranges
00
Heating set point upper limit
131
(55)
98.6~131
(37~55)
1.8
(1)
°F
(°C)
01
Heating set point lower limit
77
(25)
77~98.6
(15~37)
1.8
(1)
°F
(°C)
02
Cooling set point upper limit
71.6
(22)
64.4~71.6
(18~22)
1.8
(1)
°F
(°C)
03
Cooling set point lower limit
41
(5)
41~64.4
(5~18)
1.8
(1)
°F
(°C)
04
Installation related setting
C
Setup on EKRP1HB digital I/O PCB
00
Solar priority mode setting
0
0/1
1
—
01
Installation related setting
02
Installation related setting
03
Installation related setting
04
Installation related setting
D
Local shift value weather dependent
00
Installation related setting
01
Installation related setting
02
Installation related setting
03
Local shift value weather dependent
0
0/1/2/3/4
—
—
E
Unit information readout
00
Software version
Read
only
—
—
—
01
EEPROM version
Read
only
—
—
—
02
Unit model identification
Read
only
—
—
—
03
Liquid refrigerant temperature
Read
only
—
—
°F
(°C)
04
Inlet water temperature
Read
only
—
—
°F
(°C)
F
Installation related settings
00
Installation related setting
01
Installation related setting
02
Installation related setting
03
Installation related setting
04
Installation related setting
First
code
Second
code
Setting name
Installer setting at variance with default value
Default
value
Range
Step
Unit
Date
Value
Date
Value
4PW62569-1.book Page 16 Wednesday, June 30, 2010 12:13 PM