background image

1 General safety precautions

Installation manual

3

EKHWS150~300D3V3
Domestic hot water tank with option kit for air to water heat pump
system
4P510672-1C – 2023.02

Symbol

Explanation

Before performing maintenance and service tasks,
read the service manual.

For more information, see the installer and user
reference guide.

The unit contains rotating parts. Be careful when
servicing or inspecting the unit.

Symbols used in the documentation:

Symbol

Explanation

Indicates a figure title or a reference to it.

Example: 

"  1–3 Figure title" means "Figure 3 in

chapter 1".

Indicates a table title or a reference to it.

Example: 

"  1–3 Table title" means "Table 3 in

chapter 1".

1.2

For the installer

1.2.1

General

If  you  are  NOT  sure  how  to  install  or  operate  the  unit,  contact  your
dealer.

DANGER: RISK OF BURNING/SCALDING

▪ Do  NOT  touch  the  refrigerant  piping,  water  piping  or

internal parts during and immediately after operation. It
could  be  too  hot  or  too  cold.  Give  it  time  to  return  to
normal  temperature.  If  you  MUST  touch  it,  wear
protective gloves.

▪ Do NOT touch any accidental leaking refrigerant.

WARNING

Improper  installation  or  attachment  of  equipment  or
accessories  could  result  in  electrical  shock,  short-circuit,
leaks,  fire  or  other  damage  to  the  equipment.  ONLY  use
accessories,  optional  equipment  and  spare  parts  made  or
approved by Daikin unless otherwise specified.

WARNING

Make  sure  installation,  testing  and  applied  materials
comply  with  applicable  legislation  (on  top  of  the
instructions described in the Daikin documentation).

WARNING

Tear apart and throw away plastic packaging bags so that
nobody,  especially  NOT  children,  can  play  with  them.

Possible consequence: 

suffocation.

WARNING

Provide adequate measures to prevent that the unit can be
used  as  a  shelter  by  small  animals.  Small  animals  that
make contact with electrical parts can cause malfunctions,
smoke or fire.

CAUTION

Wear  adequate  personal  protective  equipment  (protective
gloves,  safety  glasses,…)  when  installing,  maintaining  or
servicing the system.

CAUTION

Do NOT touch the air inlet or aluminium fins of the unit.

CAUTION

▪ Do  NOT  place  any  objects  or  equipment  on  top  of  the

unit.

▪ Do NOT sit, climb or stand on the unit.

In  accordance  with  the  applicable  legislation,  it  might  be  necessary
to provide a logbook with the product containing at least: information
on maintenance, repair work, results of tests, stand-by periods,…

Also,  at  least,  following  information  MUST  be  provided  at  an
accessible place at the product:

▪ Instructions for shutting down the system in case of an emergency

▪ Name and address of fire department, police and hospital

▪ Name,  address  and  day  and  night  telephone  numbers  for

obtaining service

In Europe, EN378 provides the necessary guidance for this logbook.

1.2.2

Installation site

▪ Provide  sufficient  space  around  the  unit  for  servicing  and  air

circulation.

▪ Make sure the installation site withstands the weight and vibration

of the unit.

▪ Make  sure  the  area  is  well  ventilated.  Do  NOT  block  any

ventilation openings.

▪ Make sure the unit is level.

Do NOT install the unit in the following places:

▪ In potentially explosive atmospheres.

▪ In  places  where  there  is  machinery  that  emits  electromagnetic

waves.  Electromagnetic  waves  may  disturb  the  control  system,
and cause malfunction of the equipment.

▪ In  places  where  there  is  a  risk  of  fire  due  to  the  leakage  of

flammable  gases  (example:  thinner  or  gasoline),  carbon  fibre,
ignitable dust.

▪ In  places  where  corrosive  gas  (example:  sulphurous  acid  gas)  is

produced. Corrosion of copper pipes or soldered parts may cause
the refrigerant to leak.

1.2.3

Water

If applicable. See the installation manual or installer reference guide
of your application for more information.

NOTICE

Make  sure  water  quality  complies  with  EU  directive
2020/2184.

1.2.4

Electrical

DANGER: RISK OF ELECTROCUTION

▪ Turn OFF all power supply before removing the switch

box  cover,  connecting  electrical  wiring  or  touching
electrical parts.

▪ Disconnect the power supply for more than 10 minutes,

and measure the voltage at the terminals of main circuit
capacitors  or  electrical  components  before  servicing.
The  voltage  MUST  be  less  than  50  V  DC  before  you
can touch electrical components. For the location of the
terminals, see the wiring diagram.

▪ Do NOT touch electrical components with wet hands.

▪ Do  NOT  leave  the  unit  unattended  when  the  service

cover is removed.

Summary of Contents for EKHWS 150D3V3 Series

Page 1: ...ith option kit for air to water heat pump system English Installation manual Domestic hot water tank with option kit for air to water heat pump system EKHWS 150D3V3 EKHWS 180D3V3 EKHWS 200D3V3 EKHWS 2...

Page 2: ...inishing the domestic hot water tank installation 13 7 6 1 To close the domestic hot water tank 13 8 Commissioning 13 8 1 Checklist before commissioning 13 8 2 Checklist during commissioning 14 9 Hand...

Page 3: ...t CAUTION Do NOT place any objects or equipment on top of the unit Do NOT sit climb or stand on the unit In accordance with the applicable legislation it might be necessary to provide a logbook with t...

Page 4: ...ly stress relief and the terminal block itself MUST be as such that the current carrying wires are tautened before the earth wire is in case the power supply is pulled loose from the stress relief NOT...

Page 5: ...values to a value other than the factory default setting If you are unable to find the cause of the problem call your dealer WARNING Prevent hazards due to inadvertent resetting of the thermal cut out...

Page 6: ...tional 1 a b 1 a Expansion vessel of 18 litres 3 4 Male BSP b Instruction sheet 5 About the units and options 5 1 Identification 5 1 1 Identification label Domestic hot water tank Location Model ident...

Page 7: ...stic hot water tank meets the daily consumption of domestic hot water Domestic hot water tank After installation Immediately after installation the domestic hot water tank must be flushed with fresh w...

Page 8: ...d fuses Power supply F2B field supply 13 A 20 A 1 50 Hz 220 240 V 7 Installation 7 1 Overview Installation This chapter describes what you have to do and know on site to install the system Typical wor...

Page 9: ...Sleeve b Valve motor cover c Screw d Scale 2 The 3 way valve can be installed in accordance with one of the following four configurations 1 2 3 1 3 2 1 2 3 1 3 2 E3 E1 E2 E4 1 From unit 1 2 To DHW tan...

Page 10: ...ooster heater power supply sticker in the unit switch box on the location shown in the illustration below 2 Mount the contactor K3M and terminal block X7M Fix the contactor with the 2 contactor fixing...

Page 11: ...cessory bag in between terminals X2M 7 and X2M 8 4 Connect the earth wire of the booster heater power supply cable to the switch box earthing screw 5 Connect the N and L wires of the booster heater po...

Page 12: ...Remove the switch box cover from the tank 2 For all models except EKHWS200 execute the following steps Route the booster heater power supply cable and the thermistor cable through one of the recesses...

Page 13: ...ram sticker on the inside of the switch box lid A B N L 8 Fix the cable s using the cable clamp at the bottom of the tank to ensure strain relief 9 Install the switch box cover 7 6 Finishing the domes...

Page 14: ...ER RISK OF BURNING SCALDING WARNING Before carrying out any maintenance or repair activity ALWAYS switch off the circuit breaker on the supply panel remove the fuses or open the protection devices of...

Page 15: ...ce was activated stop the unit and find out why the safety device was activated before resetting it NEVER shunt safety devices or change their values to a value other than the factory default setting...

Page 16: ...Hot water outlet 3 4 BSP b Cold water inlet 3 4 BSP c Entering water from heat pump 3 4 BSP d Returning water to heat pump 3 4 BSP e Pressure relief valve connection 3 4 BSP f Electrical connection bo...

Page 17: ...on All international European national and local directives laws regulations and or codes that are relevant and applicable for a certain product or domain Service company Qualified company which can p...

Page 18: ......

Page 19: ......

Page 20: ...4P510672 1C 2023 02 Copyright 2017 Daikin 4P510672 1 C 0000000 Verantwortung f r Energie und Umwelt...