Installing the unit
Installation manual
EKLN140A1
8
Low sound enclosure
4P650154-1
–
2021.03
a
Self-adhesive D-rubber
4.6 Installing the panels and recirculation
seal
Parts
•
Top panel
•
Side panel, left
•
Side panel, right
•
Sealing strips
Installing the top panel
1.
Fit the 4 cage nuts (accessory Q) to the top panel from the inside
so that the panel is flat on the outside.
a
Cage nut
2.
Position the top panel. The top panel must be routed precisely
over the 4 guide pins (accessory M).
3.
Secure the top panel with 4× M5 self-tapping bolts (accessory A)
ONLY.
NOTE
Tighten them hand-tight (maximum tightening torque =
5 Nm).
4.
Fit the self-adhesive D-rubber (accessory P) to both edges of the
top panel. Fit the rubber flush with the outside of the sheet edge.
INFORMATION
Dry and degrease the steel sheet to ensure that the D-
rubber adheres properly. Cut the rubber to length with
scissors.
a
Self-adhesive D-rubber
Installing the side panels
1.
Affix the self-adhesive sealing strips to both sides of the heat
pump.
a
Sealing strip, left. Affix this over the full height of the heat pump
(see dotted line).
b
Sealing strip, right. Affix this over the length of the service door
only (see dotted line).
2.
Push the remainder of the sealing strip between the base frame
profile.
3.
Position the left and right side panels. To do this, lift both panels
into the recess and let them slide over the lower pins (accessory
M).