Self-adhesive D-rubber 

 

4.6  Installing the panels and recirculation 

seal 

Parts 

 

Top panel 

 

Side panel, left 

 

Side panel, right 

 

Sealing strips 

Installing the top panel 

1. 

Fit the 4 cage nuts (accessory Q) to the top panel from the inside 
so that the panel is flat on the outside. 

 

Cage nut 

2. 

Position the top panel. The top panel must be routed precisely 
over the 4 guide pins (accessory M). 

3. 

Secure the top panel with 4× M5 self-tapping bolts (accessory A) 
ONLY. 

 

NOTE 

 

Tighten  them  hand-tight  (maximum  tightening  torque  = 
5 Nm). 

4. 

Fit the self-adhesive D-rubber (accessory P) to both edges of the 
top panel. Fit the rubber flush with the outside of the sheet edge. 

 

INFORMATION 

 

Dry  and  degrease  the  steel  sheet  to  ensure  that  the  D-
rubber  adheres  properly.  Cut  the  rubber  to  length  with 
scissors. 

 

Self-adhesive D-rubber 

Installing the side panels 

1. 

Affix  the  self-adhesive  sealing  strips  to  both  sides  of  the  heat 
pump. 

 

Sealing strip, left. Affix this over the full height of the heat pump 
(see dotted line). 

Sealing strip, right. Affix this over the length of the service door 
only (see dotted line). 

2. 

Push the remainder of the sealing strip between the base frame 
profile. 

3. 

Position the left and right side panels. To do this, lift both panels 
into the recess and let them slide over the lower pins (accessory 
M). 

 

Summary of Contents for EKLN140A1

Page 1: ...Installation manual Low sound enclosure EKLN140A1 ...

Page 2: ...ired 2 About the box NOTE Before commencing work check the packaging and parts for damage and ensure that the shipment is complete NOTE All plate work parts are protected with protective film Remove the protective film from a part only when you are about to install it 2 1 Parts The box contains the following parts Base frame profile front 1 Base frame profile rear 1 Base frame profile left 1 Base ...

Page 3: ...on tools Cut resistant work gloves Wire cutters Utility knife Measuring tape Try square Degreaser Screwdriver torx TXP25 Pipe wrench size 10 Key size 13 Drill with 8 mm masonry bit if the foundation is made of concrete 4 2 Fitting the enclosure 4 2 1 Installing the base frame Parts Start by installing the base frame which comprises the following parts a Base frame profile front b Base frame profil...

Page 4: ...ligned with one another 4 Connect the vibration dampers e to the support beams and partitions using the M8 spring washers accessory H 5 Connect the support beams and partitions to one another using the M5 self tapping bolts accessory A NOTE Tighten them hand tight maximum tightening torque 5 Nm 6 Affix 1 strip of sealing tape accessory C to both support beams Affix this in center of the front supp...

Page 5: ...he desired aperture in the base frame for the pipes and electrical wiring 2 Seal the other openings using the base frame sealing pads provided Secure with M5 self tapping bolts accessory A and washers accessory B NOTE Tighten them hand tight maximum tightening torque 5 Nm 3 If the cables enter from the floor all openings can be sealed 4 3 2 Positioning the wiring 1 Insert the small rounded finishi...

Page 6: ...t right b Install the slats frame 1 Position the vertical supports left a and vertical support right b on the base frame 2 Secure with M5 self tapping bolts accessory A and washers accessory B NOTE Tighten them hand tight maximum tightening torque 5 Nm 3 Fit the plastic guide pins accessory M to the bottom of the vertical support 4 Secure with M5 self tapping bolts accessory A and washers accessor...

Page 7: ... and washer Install the upper slats 1 The upper slats are positioned by tilting them into the vertical supports Firstly place the slat at the top over the vertical supports Then slide the slat into the notches below in the vertical supports 2 Secure the 8 guide pins accessory M with the M5 self tapping bolts accessory A A washer is not needed in this case illustration a 3 Fit a 12 7 spacer bush ac...

Page 8: ...ing torque 5 Nm 4 Fit the self adhesive D rubber accessory P to both edges of the top panel Fit the rubber flush with the outside of the sheet edge INFORMATION Dry and degrease the steel sheet to ensure that the D rubber adheres properly Cut the rubber to length with scissors a Self adhesive D rubber Installing the side panels 1 Affix the self adhesive sealing strips to both sides of the heat pump...

Page 9: ...9 2 RZA200 250D7Y1B 2 79 2 RXYSA4 5 6A7 2 18 2 INFORMATION For further information on the field settings see the installer reference guide or the service manual for the unit 4 8 Maintenance The low sound enclosure is free of maintenance under normal conditions Clean the outside with water and a mild cleaning agent at regular intervals to keep the housing in optimal condition So as not to impair th...

Page 10: ......

Page 11: ......

Page 12: ...4P650154 1 2021 03 Copyright 2021 Daikin 4P650154 1 0000000J ...