22
Configuration
Configuration
6.5
Programming a schedule
You can create a schedule with time slots for heating and
cooling according to your personal needs. For further infor-
mation, see the DHC Application Guide.
6.5.1 Heating or cooling
You can use your floor heating system to heat or cool
rooms, provided your Daikin Altherma unit supports it.
6.5.2 Week schedule
In the week schedule, you can set up to 6 time slots (13
change settings) for each weekday separately. The pro-
gramming is carried out for the selected days, for which
temperature settings have to be set for the entire period
between 00:00 and 23:59h.
6.5.3 Optimum start/stop function
With the optimum start/stop you can reach the desired tem-
perature in the room at the defined time. This function is
activated by default and cannot be turned off.
6.6
Offset temperature (not yet available)
As the temperature is measured on the DHC Room
Thermostat, the temperature distribution can vary through-
out a room. To adjust this, a temperature offset of ±3.5 °C
can be set. If a nominal temperature of e.g. 20 °C is set
but the room presents with only 18 °C, an offset of -2.0 °C
needs to be set. An offset temperature of 0.0 °C is set in
the factory settings.
This setting is not yet available in the ONECTA app
and cannot be changed for the moment.
6.7
Selecting a temperature display (not yet
available)
You can choose which temperature will be displayed on the
accessory. There are 3 options:
• display the actual temperature,
• display the setpoint temperature, or
• display the actual temperature and humidity alter-
nately.
This setting is not yet available in the ONECTA app
and cannot be changed for the moment.
Summary of Contents for EKRCTRDI3BA
Page 1: ...Installer and user reference guide Daikin Home Controls Room Thermostat 2 EKRCTRDI3BA...
Page 2: ...2 1 A F C D E B...
Page 3: ...4 3 G H I J I J...
Page 4: ...6 5 K...
Page 5: ...8 7...
Page 36: ...Free download of the ONECTA app 4P687366 1 2022 04...