17
Operation
No. Description
Setting
010
Heating system
Sets the existing heating system:
• Floor heating, standard (FBH St.)
• Floor heating, low energy (FBH NE)
• Radiator (RAD)
• Convector, passive (KON pas)
• Convector, active (KON akt)
0 = FBH St.
1 = FBH NE
2 = RAD
3 = KON pas
4 = KON akt
Standard: 0
020
Disable cooling
Deactivates the cooling function.
0 = activated
1 = deactivated
Standard: 0
030
Operating lock
Protects the deactivation of the operating
lock with a PIN.
0 = deactivated
1 = activated
Standard: 0
031
PIN operating lock
Sets the PIN for parameter 30.
0 ... 9999
Standard: 1234
If PIN is unknown:
De-energise the device.
Hold down the dial and apply
voltage again until the software
version is shown on the display
and goes out again.
Press the dial again until the
symbol disappears.
032
Restricted operation
Switches the room control unit operating
lock between “Standard” and “Restricted
operation”.
0 = deactivated
1 = activated
Standard: 0
050
Duration of the display illumination
Sets the duration of further illumination of
the display after use.
0 ... 30 sec.
in 5 second incre-
ments
Standard: 15 sec.
090
Signalling of switching output
Signals the control of switching outputs by
a fl ashing heating resp. cooling symbol.
0 = deactivated
1 = activated
Standard: 1