CONFIGURING THE DAIKIN
ENVi THERMOSTAT
The first step after installing the Daikin ENVi
thermostat is to configure the thermostat
settings for the Indoor Unit.
Preferences
This section describes the user preferences that
should be configured during installation. For a
complete description of all user preferences, see
the Daikin ENVi User Manual.
Intelligent Eye
Some models of the Indoor Unit include an
intelligent eye, an infrared sensor that detects
room occupancy. It adjust the set point by 3.6°F
(2°C) if no movement is detected in order to
save energy (+3.6°F/+2°C if cooling, –3.6°F/–2°C
if heating).
To use intelligent eye, you must enable this
option in the Daikin ENVi thermostat and
then enable it with the Daikin wireless remote
controller. If enabled, the thermostat’s Smart
Recovery and Temp Alert functions are not
available.
By default, intelligent eye is disabled on the
thermostat.
Do NOT enable the intelligent eye with the Daikin
wireless remote controller when it is disabled on
the thermostat as this may cause suboptimal
operation and result in invalid recovery and alert
messages. Also, if an auxiliary heater is configured,
enabling intelligent eye may energize the auxiliary
heater more often than would normally be
required.
To configure the
intelligent eye:
From the Home screen,
press
MENU
.
Select
Settings
▶
Preferences.
Select
Intelligent Eye.
Enable (
Yes
) or disable
(
No
) the intelligent eye
sensor.
16