12/12
Breadcrumb
Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
9.I
[E-07]
R/W
0~8
0 OSO tank 150/180
1 FS with BUH
2 FS with BSH
3 OSO tank 200/250/300
4 Rotex without BSH (HYB)
5 Rotex with BSH
6 Third party tank for HYB
7 Third party tank, coil >= 1,05m2
8 Third party tank, coil >= 1,8m2
9.I
[E-08]
R/W
0: No
1: Yes
9.I
[E-09]
1
9.I
[E-0B]
R/W
0: not installed
1: -
2: Bizone kit installed
9.I
[E-0C]
R/W
0: Without hydraulic separator / no
direct pump
1: With hydraulic separator / no direct
pump
2: With hydraulic separator / with direct
pump
9.I
[E-0D]
R/W
0: No
1: Yes
9.I
[E-0E]
0
9.I
[F-00]
R/W
0: Restricted
1: Allowed
9.I
[F-01]
R/W
10~35°C, step: 1°C
20°C
9.I
[F-02]
3
9.I
[F-03]
5
9.I
[F-04]
0
9.I
[F-05]
0
9.I
[F-06]
R/W
0: Disabled
1: Enabled
9.I
[F-07]
R/W
0: Enabled
1: Disabled
9.I
[F-08]
R/W
0: Disabled
1: Enabled
9.I
[F-09]
R/W
0: Disabled
1: Enabled
9.I
[F-0A]
0
9.I
[F-0B]
R/W
0: No
1: Yes
9.I
[F-0C]
R/W
0: No
1: Yes
9.I
[F-0D]
R/W
0: Continuous
1: Sample
2: Request
9.I
[F-0E]
R/W
10~35 kW, step: 1kW
20 kW
Bi-zone kit settings
9.P.1
[E-0B]
R/W
0: not installed
1: -
2: Bizone kit installed
9.P.2
[E-0C]
R/W
0: Without hydraulic separator / no
direct pump
1: With hydraulic separator / no direct
pump
2: With hydraulic separator / with direct
pump
9.P.3
[7-0A]
R/W
20~95%, step 5%
95%
9.P.4
[7-0B]
R/W
20~95%, step 5%
95%
9.P.5
[7-0C]
R/W
20~300 sec, step 5 sec
125 sec
Main zone pump fixed PWM
--
Pump operation allowed outside range.
--
--
Bi-zone system type
What kind of DHW tank is installed?
Continuous heating defrost enable
Is a bi-zone kit installed?
Pump operation during flow abnormality.
--
Close shut-off valve during thermo OFF?
Bi-zone kit installed
Is the system filled with glycol ?
Enable Tank Boiler?
Efficiency calculation
What bizone system type is installed?
Mixing valve turning time
What is the pump operation mode?
Above which outdoor temperature is cooling allowed?
--
--
Power saving function for outdoor unit.
--
Close shut-off valve during cooling?
Add zone pump fixed PWM
Tank heating support_max
4P681207-1 - 2021.12
(*1) 300 Tank_(*2) 500 Tank_
(*3) *X*_(*4) *H*_(*5) *B*_
(*6) *EKECBUA3V*_(*7) *EKECBUA6V*_(*8) *EKECBUA9W*_(*9) BUH less_
(*10) 04P_(*11) 08P