background image

3 General information

Operation manual

6

ET9W

Daikin Altherma 3 H MT F

4P634884-1 – 2021.03

3

General information

3.1

About this document

Thank you for purchasing this product. Please:

▪ Read  the  documentation  carefully  before  operating  the  user

interface to ensure the best possible performance.

▪ Request the installer to inform you about the settings that he used

to  configure  your  system.  Check  if  he  has  filled  in  the  installer
settings tables. If NOT, request him to do so.

▪ Keep the documentation for future reference.

Target audience

End users

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you must read before installing

▪ Format: Paper (in the box of the indoor unit)

Operation manual:

▪ Quick guide for basic usage

▪ Format: Paper (in the box of the indoor unit)

User reference guide:

▪ Detailed  step-by-step  instructions  and  background  information

for basic and advanced usage

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Installation manual – Outdoor unit:

▪ Installation instructions

▪ Format: Paper (in the box of the outdoor unit)

Installation manual – Indoor unit:

▪ Installation instructions

▪ Format: Paper (in the box of the indoor unit)

Installer reference guide:

▪ Preparation  of  the  installation,  good  practices,  reference

data, …

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Addendum book for optional equipment:

▪ Additional info about how to install optional equipment

▪ Format:  Paper  (in  the  box  of  the  indoor  unit)  +  Digital  files  on

http://www.daikineurope.com/support-and-manuals/product-
information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your installer.

The original documentation is written in English. All other languages
are translations.

Daikin Residential Controller app

If set up by your installer, you can use the
Daikin Residential Controller app to control and
monitor the status of your system. For more
information, see:

http://www.onlinecontroller.daikineurope.com/

Breadcrumbs

Breadcrumbs  (example: 

[4.3]

)  help  you  to  locate  where  you  are  in

the menu structure of the user interface.

1

To 

enable

 the breadcrumbs: In the home screen or

main menu screen, press the help button. The
breadcrumbs appear in the top left corner of the
screen.

2

To 

disable

 the breadcrumbs: Press the help button

again.

This document also mentions these breadcrumbs. 

Example:

1

Go to 

[4.3]

Space heating/cooling

 > 

Operation

range

.

This means:

1

Starting from the home screen, turn the left dial and
go to 

Space heating/cooling

.

4

Space heating/cooling

2

Press the left dial to enter the submenu.

3

Turn the left dial and go to 

Operation range

.

Operation range

4.3

4

Press the left dial to enter the submenu.

3.2

About the system

Depending on the system layout, the system can:

▪ Heat up a space

▪ Cool  down  a  space  (if  a  heating/cooling  heat  pump  model  is

installed)

▪ Produce domestic hot water

INFORMATION

Cooling  is  only  applicable  in  case  a  conversion  kit
(EKHVCONV*) is installed.

Summary of Contents for ETVZ12S18EA6V ETVZ12S23EA6V

Page 1: ...Operation manual Daikin Altherma 3 H MT F English Operation manual Daikin Altherma 3 H MT F ETVZ12S18EA6V ETVZ12S23EA6V ETVZ12S18EA9W ETVZ12S23EA9W...

Page 2: ...her dependent curve 15 4 9 2 2 points curve 16 4 9 3 Slope offset curve 16 4 9 4 Using weather dependent curves 17 5 Energy saving tips 17 6 Maintenance and service 18 6 1 Overview Maintenance and ser...

Page 3: ...OFF space heating cooling operation C 2 Operation Space heating cooling room frost protection operation if enabled can still activate However for leaving water temperature control and external room th...

Page 4: ...the new preferred temperature at X1 is unequally higher than the preferred temperature at X2 X1 X2 c d Y1 Y2 Y3 Y4 a b Offset When offset is changed the new preferred temperature at X1 is equally high...

Page 5: ...nge the tank temperature setpoint In Reheat only mode you can use the tank temperature setpoint screen to read out and adjust the domestic hot water temperature 1 Go to 5 Tank Tank 5 2 Adjust the dome...

Page 6: ...duct information Addendum book for optional equipment Additional info about how to install optional equipment Format Paper in the box of the indoor unit Digital files on http www daikineurope com supp...

Page 7: ...urred See 7 1 To display the help text in case of a malfunction 418 for more information LCD screen The LCD screen has a sleeping function After 15 min of non interaction with the user interface the s...

Page 8: ...nt 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 7 2 Time date Hours Minutes Year Month Day Daylight savings time Format 7 3 Holiday Activation From Till 7 4 Quiet...

Page 9: ...failure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available via solar panels or smart grid e2 Smart energy is currentl...

Page 10: ...in zone Shows the applicable symbol for your main zone emitter type Set the leaving water temperature for the main zone 3 Additional zone Restriction Only displayed if there are two leaving water temp...

Page 11: ...ng operation ON b Space heating cooling operation OFF Tank heating operation 55 21 35 45 c 55 21 35 45 d c Tank heating operation ON d Tank heating operation OFF 4 4 2 To turn ON or OFF Space heating...

Page 12: ...following options Heating Only heating mode Cooling Only cooling mode Automatic The operation mode changes automatically between heating and cooling based on the outdoor temperature Restricted per mo...

Page 13: ...ed to heat up the water to a preset value example Comfort 60 C During the morning you consume hot water and the DHW tank temperature decreases At 14 00 the DHW tank is programmed to heat up the water...

Page 14: ...ule to the other weekdays 5 Program the schedule for Saturday and copy it to Sunday 6 Give the schedule a name To go to the schedule 1 Go to 1 1 Room Schedule 2 Set scheduling to Yes 3 Go to 1 2 Room...

Page 15: ...and confirm the selected character The schedule name can contain up to 15 characters 5 Confirm the new name INFORMATION Not all schedules can be renamed 4 9 Weather dependent curve 4 9 1 What is a wea...

Page 16: ...and proceed 4 9 3 Slope offset curve Slope and offset Define the weather dependent curve by its slope and offset Change the slope to differently increase or decrease the temperature of the leaving wat...

Page 17: ...one Cooling WD curve Additional zone Heating 3 5 Additional zone Heating WD curve Additional zone Cooling 3 6 Additional zone Cooling WD curve Zone Go to Tank Restriction Only available to installers...

Page 18: ...gerant total refrigerant charge in kg 1000 Please contact your installer for more information WARNING FLAMMABLE MATERIAL The refrigerant inside this unit is mildly flammable WARNING Do NOT pierce or b...

Page 19: ...t water heating and space heating stops To manually recover it via the user interface go to the Malfunctioning main menu screen and confirm whether the backup heater can take over the heat load or not...

Page 20: ...of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUST be treated at a specialised treatment facility for reuse recycling and recovery 9 Glos...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...4P634884 1 2021 03 Copyright 2021 Daikin 4P634884 1 0000000V Verantwortung f r Energie und Umwelt...

Reviews: