16
|
Technical data
Installer reference guide
259
EPRA14~18D + ET23E
Daikin Altherma 3 H HT F
4P644739-1A – 2022.03
Y3S
Solenoid valve (hot gas bypass)
Y4S
Solenoid valve (liquid injection)
Z1C~Z11C
Noise filter (ferrite core)
Z1F~Z6F (A1P, A2P)
Noise filter
Legend in case of W1 models:
A1P
Printed circuit board (main)
A2P
Printed circuit board (noise filter)
A3P
Printed circuit board (leakage current)
A4P
Printed circuit board (ACS)
A5P
Printed circuit board (inverter)
BS1~BS4 (A1P)
Push button switch
C1~C3 (A2P)
Capacitor
DS1 (A1P)
DIP switch
E1H
Drain tube heater (field supply)
E1HHEX
Plate heat exchanger heater
F1U
Field fuse (field supply)
F1U~F7U (A1P, A2P)
Fuse
H1P~H7P (A1P)
Light-emitting diode (service monitor is orange)
HAP (A1P, A2P)
Light-emitting diode (service monitor is green)
K1R (A1P)
Magnetic relay (Y1S)
K1R (A2P)
Magnetic relay
K1R (A4P)
Magnetic relay (E1HHEX)
K2R (A1P)
Magnetic relay (Y2S)
K2R (A4P)
Magnetic relay (E1H)
K3R (A1P)
Magnetic relay (Y3S)
K4R (A1P)
Magnetic relay (E1HC)
K2M, K11M (A2P)
Magnetic contactor
L1R~L4R
Reactor
M1C
Compressor motor
M1F
Fan motor
PS (A2P)
Switching power supply
Q1DI
Earth leakage circuit breaker (30 mA) (field supply)
R1, R2 (A2P)
Resistor
R1T
Thermistor (outdoor air)
R2T
Thermistor (compressor discharge)
R3T
Thermistor (compressor suction)
R4T
Thermistor (air heat exchanger, distributor)
R5T
Thermistor (air heat exchanger, middle)