10 Technical data
Installation manual
36
ET9W
Daikin Altherma 3 H HT F
4P644730-1 – 2021.02
Translation of text on wiring diagram
English
Translation
(1) Main power connection
(1) Main power connection
For HP tariff
For preferential kWh rate power
supply
Indoor unit supplied from outdoor Indoor unit supplied from outdoor
Normal kWh rate power supply
Normal kWh rate power supply
Only for normal power supply
(standard)
Only for normal power supply
(standard)
Only for preferential kWh rate
power supply (outdoor)
Only for preferential kWh rate
power supply (outdoor)
Outdoor unit
Outdoor unit
Preferential kWh rate power
supply contact: 16 V DC
detection (voltage supplied by
PCB)
Preferential kWh rate power
supply contact: 16 V DC
detection (voltage supplied by
PCB)
SWB
Switch box
Use normal kWh rate power
supply for indoor unit
Use normal kWh rate power
supply for indoor unit
(2) Backup heater power supply
(2) Backup heater power supply
(3) User interface
(3) User interface
Only for ***
Only for ***
Only for remote user interface
Only for the user interface used
as room thermostat
SD card
Card slot for WLAN cartridge
WLAN cartridge
WLAN cartridge
(5) Ext. thermistor
(5) External thermistor
SWB
Switch box
(6) Field supplied options
(6) Field supplied options
12 V DC pulse detection (voltage
supplied by PCB)
12 V DC pulse detection (voltage
supplied by PCB)
230 V AC Control Device
230 V AC Control Device
230 V AC supplied by PCB
230 V AC supplied by PCB
Continuous
Continuous current
DHW pump output
Domestic hot water pump output
DHW pump
Domestic hot water pump
Electrical meters
Electrical meters
For HV smartgrid
For high voltage Smart Grid
For LV smartgrid
For low voltage Smart Grid
For safety thermostat
For safety thermostat
For safety thermostat
For safety thermostat
For smartgrid
For Smart Grid
Inrush
Inrush current
Max. load
Maximum load
Normally closed
Normally closed
Normally open
Normally open
Safety thermostat contact: 16 V
DC detection (voltage supplied
by PCB)
Safety thermostat contact:
16 V DC detection (voltage
supplied by PCB)
Shut-off valve
Shut-off valve
Smartgrid contacts
Smart Grid contacts
Smartgrid PV power pulse meter Smart Grid photovoltaic power
pulse meter
SWB
Switch box
(7) Option PCBs
(7) Option PCBs
Alarm output
Alarm output
Changeover to ext. heat source
Changeover to external heat
source
Max. load
Maximum load
Min. load
Minimum load
Only for demand PCB option
Only for demand PCB option
Only for digital I/O PCB option
Only for digital I/O PCB option
Options: external heat source
output, solar pump connection,
alarm output
Options: external heat source
output, solar pump connection,
alarm output
Options: On/OFF output
Options: On/OFF output
Power limitation digital inputs: 12
V DC / 12 mA detection (voltage
supplied by PCB)
Power limitation digital inputs:
12 V DC / 12 mA detection
(voltage supplied by PCB)
Refer to operation manual
Refer to the operation manual
Solar input
Solar input
Solar pump connection
Solar pump connection
Space C/H On/OFF output
Space cooling/heating On/OFF
output
SWB
Switch box
(8) External On/OFF thermostats
and heat pump convector
(8) External On/OFF thermostats
and heat pump convector
Additional LWT zone
Additional leaving water
temperature zone
Main LWT zone
Main leaving water temperature
zone
Only for external sensor (floor/
ambient)
Only for external sensor (floor or
ambient)
Only for heat pump convector
Only for heat pump convector
Only for wired On/OFF
thermostat
Only for wired On/OFF
thermostat
Only for wireless On/OFF
thermostat
Only for wireless On/OFF
thermostat