background image

11

 | 

Glossary

User reference guide

56

EWAA011~016DA + EWYA009~016DA

Packaged air-cooled water chillers

and packaged air to water heat pumps

4P620246-1 – 2020.06

11 Glossary

DHW = Domestic hot water

Hot water used, in any type of building, for domestic purposes.

LWT = Leaving water temperature

Water temperature at the water outlet of the unit.

Dealer

Sales distributor for the product.

Authorised installer

Technical skilled person who is qualified to install the product.

User

Person who is owner of the product and/or operates the product.

Applicable legislation

All international, European, national and local directives, laws, regulations
and/or codes that are relevant and applicable for a certain product or
domain.

Service company

Qualified company which can perform or coordinate the required service to
the product.

Installation manual

Instruction manual specified for a certain product or application, explaining
how to install, configure and maintain it.

Operation manual

Instruction manual specified for a certain product or application, explaining
how to operate it.

Accessories

Labels, manuals, information sheets and equipment that are delivered with
the product and that need to be installed according to the instructions in
the accompanying documentation.

Optional equipment

Equipment made or approved by Daikin that can be combined with the
product according to the instructions in the accompanying documentation.

Field supply

Equipment NOT made by Daikin that can be combined with the product
according to the instructions in the accompanying documentation.

Summary of Contents for EWAA-DV1P

Page 1: ...de Packaged air cooled water chillers and packaged air to water heat pumps EWAA011 016DAV3P EWAA011 016DAW1P EWAA011 016DAV3P H EWAA011 016DAW1P H EWYA009 016DAV3P EWYA009 016DAW1P EWYA009 016DAV3P H...

Page 2: ...Determining which temperature control you are using 28 5 6 4 To change the desired room temperature 28 5 6 5 To change the desired leaving water temperature 29 5 7 Preset values and schedules 30 5 7 1...

Page 3: ...of contents User reference guide 3 EWAA011 016DA EWYA009 016DA Packaged air cooled water chillers and packaged air to water heat pumps 4P620246 1 2020 06 12 1 Configuration wizard 57 12 2 Settings me...

Page 4: ...outdoor unit Operation manual Quick guide for basic usage Format Paper in the box of the outdoor unit User reference guide Detailed step by step instructions and background information for basic and a...

Page 5: ...e home screen or main menu screen press the help button The breadcrumbs appear in the top left corner of the screen 2 To disable the breadcrumbs Press the help button again This document also mentions...

Page 6: ...njury NOTICE Indicates a situation that could result in equipment or property damage INFORMATION Indicates useful tips or additional information Symbols used on the unit Symbol Explanation Before inst...

Page 7: ...ysical sensory or mental capabilities or lack of experience and knowledge can only use this appliance if they have been given supervision or instruction concerning the use of the appliance by a person...

Page 8: ...that the batteries may NOT be mixed with unsorted household waste If a chemical symbol is printed beneath the symbol this chemical symbol means that the battery contains a heavy metal above a certain...

Page 9: ...le heating devices ventilate the room and contact the dealer where you purchased the unit Do NOT use the unit until a service person confirms that the part from which the refrigerant leaked has been r...

Page 10: ...licable in case of reversible models INFORMATION If underfloor heating is installed in the main zone then in cooling mode the main zone can only provide refreshment Real cooling is then NOT allowed 3...

Page 11: ...tandard mode Advanced user You can read out and edit more information To change the user permission level 1 Go to B User profile User profile B 2 Enter the applicable pin code for the user permission...

Page 12: ...n OFF space heating cooling operation C 2 Operation Space heating cooling room frost protection if enabled will remain active NOTICE Water pipe freeze prevention Even if you turn OFF space heating coo...

Page 13: ...er temperature setpoint screen to read out and adjust the desired leaving water temperature 1 Go to 2 Main zone or 3 Additional zone Main zone 2 Additional zone 3 2 Adjust the desired leaving water te...

Page 14: ...temperature at X2 X1 X2 c d Y1 Y2 Y3 Y4 a b Offset When offset is changed the new preferred temperature at X1 is equally higher as the preferred temperature at X2 Y1 Y2 Y3 Y4 X1 X2 a b c d X1 X2 Outd...

Page 15: ...DA EWYA009 016DA Packaged air cooled water chillers and packaged air to water heat pumps 4P620246 1 2020 06 5 4 Turning operation ON or OFF 424 5 6 Space heating cooling control 426 5 7 Preset values...

Page 16: ...be used for SD cards USB connector With a USB memory stick the installer can Update the software This requires a correct config file on the USB memory stick Import the settings generated by E Configu...

Page 17: ...ress the left dial Confirm your choice or go to a submenu b Back button Press to go back 1 step in the menu structure c Home button Press to go back to the home screen d Help button Press to show a he...

Page 18: ...tion Schedule Level 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 4 Space heating cooling Operation mode Operation mode schedule 1 9 Room comfort setpoint Heating...

Page 19: ...2 Detailed screen with values c3 Screen with weather dependent curve c4 Screen with schedule 5 3 1 Home screen Press the button to go back to the home screen You see an overview of the unit configurat...

Page 20: ...25 Measured outdoor temperature a e2 Quiet mode active e3 Outdoor unit f Main zone f1 Installed room thermostat type Unit operation is decided based on the ambient temperature of the dedicated Human C...

Page 21: ...setpoint a i Malfunction A malfunction occurred See 8 1 To display the help text in case of a malfunction 451 for more information a If the corresponding operation for example space heating is not ac...

Page 22: ...if present 4 Space heating cooling Shows the applicable symbol of your unit Put the unit in heating mode or cooling mode You cannot change the mode on cooling only models 7 User settings Gives access...

Page 23: ...een Go through the list of the submenu Go to the submenu Adjust and automatically apply the desired temperature Item Description Minimum temperature limit a1 Fixed by the unit a2 Restricted by the ins...

Page 24: ...onfirm changes and proceed 5 4 Turning operation ON or OFF 5 4 1 Visual indication Certain functionalities of the unit can be enabled or disabled separately If a functionality is disabled the correspo...

Page 25: ...ipe freeze prevention Even if you turn OFF space heating cooling operation C 2 Operation Space heating cooling water pipe freeze prevention if enabled will remain active 1 Go to C 2 Operation Space he...

Page 26: ...ontrol Leaving water temperature control External room thermostat control 5 6 2 Setting the space operation mode About space operation modes Your unit can be a cooling or a heating cooling model If yo...

Page 27: ...o check which space operation mode is currently used The space operation mode is displayed on the home screen When the unit is in heating mode the icon is shown When the unit is in cooling mode the ic...

Page 28: ...r To determine which temperature control you are using method 2 You can see on the home screen which temperature control you are using 25 26 Jun 2020 18 19 22 20 12 a2 a1 b a1 Heat emitter of the main...

Page 29: ...ue whenever a scheduled action occurs You can avoid scheduled behaviour by temporarily turning off scheduling To turn off room temperature scheduling 1 Go to 1 1 Room Schedule 2 Select No 5 6 5 To cha...

Page 30: ...cheduled action occurs You can avoid scheduled behaviour by temporarily turning off scheduling To turn off leaving water temperature scheduling 1 Go to one of the following 2 1 Main zone Schedule 3 1...

Page 31: ...ming schedules About schedules Depending on your system layout and installer configuration schedules for multiple controls may be available You can See Set if a specific control needs to act according...

Page 32: ...am your own schedule Activation screen For most controls a schedule is only effective if it activated in its corresponding activation screen This entry shows you where to activate it Possible actions...

Page 33: ...the additional zone On When the system is allowed to heat up the additional zone 3 3 Additional zone Cooling schedule Schedule for when the system is allowed to cool down the additional zone in coolin...

Page 34: ...main zone INFORMATION The procedures to program other schedules are similar To program the schedule overview Example You want to program the following schedule Mon Sat Wed Fri Thu Tue Sun User define...

Page 35: ...n Sat Wed Fri Thu Tue Sun User defined 1 2 Select Delete Delete Rename Select 3 Select OK to confirm To clear the content of a day schedule 1 Select the day of which you want to clear the content For...

Page 36: ...12 24 Mon Note To clear an action set its time as the time of the previous action 4 Confirm the changes Result The schedule for Monday is defined The value of the last action is valid until the next p...

Page 37: ...ined 1 C 5 Repeat this action for all other weekdays Mon Sat Wed Fri Thu Tue Sun User defined 1 C To program the schedule for Saturday and copy it to Sunday 1 Select Saturday 2 Select Edit 3 Use the l...

Page 38: ...can contain up to 15 characters 5 Confirm the new name INFORMATION Not all schedules can be renamed Usage example You work in a 3 shift system If you work in a 3 shift system you can do the following...

Page 39: ...s according to your electricity supplier 3 Confirm the changes INFORMATION The values correspond with the electricity price values for High Medium and Low previously set If no schedule is set the elec...

Page 40: ...operation The unit operates weather dependent if the desired leaving water temperature is determined automatically by the outdoor temperature It therefore is connected to a temperature sensor on the N...

Page 41: ...rrectly configure the setpoint of the main zone and additional zone See 5 8 4 Using weather dependent curves 443 5 8 2 2 points curve Define the weather dependent curve with these two setpoints Setpoi...

Page 42: ...ing water for different ambient temperatures For example if leaving water temperature is always a bit too cold at different ambient temperatures shift the offset up to equally increase the leaving wat...

Page 43: ...the setpoint mode To use the weather dependent curve you need to define the correct setpoint mode Go to setpoint mode Set the setpoint mode to Main zone Heating 2 4 Main zone Setpoint mode WD heating...

Page 44: ...hed the curve flattens out To fine tune the weather dependent curve slope offset curve The following table describes how to fine tune the weather dependent curve of a zone You feel Fine tune with slop...

Page 45: ...t mode schedule INFORMATION If the outdoor temperature is below zero we recommend to NOT use the most quiet level To check if quiet mode is active If is displayed on the home screen quiet mode is acti...

Page 46: ...configure the holiday 1 Activate the holiday mode Go to 7 3 1 User settings Holiday Activation Activation Till 7 3 1 From Select On 2 Set the first day of your holiday Go to 7 3 2 From Select a date...

Page 47: ...D 4 Remove from cloud D 5 Home network connection D 6 Cloud connection D 1 Mode Turn AP mode ON WLAN cartridge active as access point 1 Go to D 1 Wireless gateway Mode 2 In the Enable AP mode screen s...

Page 48: ...aged air to water heat pumps 4P620246 1 2020 06 2 Read out the connection status Disconnected from WLAN_SSID Connected to WLAN_SSID D 6 Cloud connection Read out the status of the connection to the cl...

Page 49: ...temperature and do NOT let the room temperature drop too low rise too high It will take more time and energy to heat up cool down the room again Use a weekly schedule for your normal space heating or...

Page 50: ...nes GWP value of the refrigerant total refrigerant charge in kg 1000 Please contact your installer for more information WARNING MILDLY FLAMMABLE MATERIAL The refrigerant inside this unit is mildly fla...

Page 51: ...of a malfunction In case of a malfunction the following will appear on the home screen depending on the severity Error Malfunction You can get a short and a long description of the malfunction as fol...

Page 52: ...t failure When the heat pump fails to operate the optional external backup heater kit can serve as an emergency heater It then takes over the heat load either automatically or by manual interaction Wh...

Page 53: ...f or is displayed on the home screen of the user interface See 8 1 To display the help text in case of a malfunction 451 for more information about the malfunction a We recommend to purge air with the...

Page 54: ...water chillers and packaged air to water heat pumps 4P620246 1 2020 06 9 Relocation 9 1 Overview Relocation If you want to relocate parts of your system contact your installer You can find the contac...

Page 55: ...air to water heat pumps 4P620246 1 2020 06 10 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with ap...

Page 56: ...a certain product or domain Service company Qualified company which can perform or coordinate the required service to the product Installation manual Instruction manual specified for a certain produc...

Page 57: ...gency 9 5 Number of zones 4 4 Glycol Filled system overview field setting E 0D Backup heater Voltage 9 3 2 Configuration 9 3 3 Capacity step 1 9 3 4 Additional capacity step 2 9 3 5 if applicable Main...

Page 58: ...es to be filled in by installer User reference guide 58 EWAA011 016DA EWYA009 016DA Packaged air cooled water chillers and packaged air to water heat pumps 4P620246 1 2020 06 Setting Fill in Informati...

Page 59: ......

Page 60: ...4P620246 1 2020 06 Copyright 2020 Daikin Verantwortung f r Energie und Umwelt...

Reviews: