ESIE10-01
General Outline
1–13
3
1
4
5
Compressor hour run meter.
General fault
- Alarm relay.
Set-point reset
- The leaving water temperature set-point can be overwritten with the following
options: 4-20 mA from external source (by user); outside ambient temperature; evaporator water
temperature
Δ
t.
Demand limit
- User can limit the load of the unit by 4-20 mA signal or by network system.
Alarm from external device
- Microprocessor is able to receive an alarm signal from an external
device (pump etc.…). User can decide if this alarm signal will or will not stop the unit.
Main switch interlock door.
Emergency stop.
Fans circuit breakers
- Safety device against motor overloading and short circuit.
Options (on
request)
Total heat recovery
- Produced with plate to plate heat exchangers to produce hot water.
Partial heat recovery
- Produced with plate to plate heat exchangers installed between the
compressor discharge and the condenser coil, allowing to produce hot water.
Soft starter
- Electronic starting device to reduce the mechanical stress during compressor start-up.
Brine version
- Allows the unit to operate down to -8°C leaving liquid temperature (antifreeze
required).
Compressor thermal overload relays
- Safety devices against compressor motor overloading. This
device together with internal motor protection (standard) guarantee the best safety system for
compressor motor.
Under/Over Voltage
- This device controls the voltage value of power supply and stops the chiller if
the value exceeds the allowed operating limits.
Ampere / Volt meter
- Device installed inside the control box showing ampere and volt values.
Capacitors for power factor correction
- To increase the operating power factor of the unit at
nominal operating conditions. The capacitors are "dry" self-regenerating type with over pressure
disconnecting safety device insulated with a no toxic dielectric mix with no PCB or PCT.
Current limit
- To limit maximum absorbed current of the unit whenever is required.
Fan speed regulation
- To control the fan speed revolution for smooth operating control of the unit.
This option improves the sound level of the unit during low ambient temperature operation.
Speedtrol
- Continuous fan speed modulation on the first fan of each circuit. It allows the unit to work
with air temperature down to -18°C.
Condenser coil guards.
Compressor and evaporator area guards.
Cu-Cu condensing coils
- To give better protection against corrosion by aggressive environments.
Cu-Cu-Sn condensing coils
- To give better protection against corrosion in aggressive environments
and by salty air.
Alucoat condensing coils
- Fins are protected by a special acrylic paint with a high resistance to
corrosion.
Summary of Contents for EWAD620-C17C-SL
Page 2: ......
Page 8: ...ESIE10 01 1 2 Part 1 System Outline 3 1 1 5 ...
Page 111: ...ESIE10 01 General Outline Part 1 System Outline 1 105 3 1 4 5 1 36 1 Power Compressor 1 2 ...
Page 112: ...General Outline ESIE10 01 1 106 Part 1 System Outline 3 1 1 4 5 1 36 2 Power Compressor 3 ...
Page 113: ...ESIE10 01 General Outline Part 1 System Outline 1 107 3 1 4 5 1 36 3 Kit Pumps ...
Page 122: ...General Outline ESIE10 01 1 116 Part 1 System Outline 3 1 1 4 5 1 36 12 Digital Inputs Board ...
Page 123: ...ESIE10 01 General Outline Part 1 System Outline 1 117 3 1 4 5 1 36 13 Digital Outputs Board ...
Page 124: ...General Outline ESIE10 01 1 118 Part 1 System Outline 3 1 1 4 5 1 36 14 Digital Outputs Board ...
Page 131: ...ESIE10 01 General Outline Part 1 System Outline 1 125 3 1 4 5 1 36 21 EEXV Compressor 1 ...
Page 134: ...General Outline ESIE10 01 1 128 Part 1 System Outline 3 1 1 4 5 1 36 24 EEXV Compressor 2 ...
Page 137: ...ESIE10 01 General Outline Part 1 System Outline 1 131 3 1 4 5 1 36 27 EEXV Compressor 3 ...
Page 138: ...General Outline ESIE10 01 1 132 Part 1 System Outline 3 1 1 4 5 1 36 28 Pumps Control ...
Page 139: ...ESIE10 01 General Outline Part 1 System Outline 1 133 3 1 4 5 1 36 29 Terminals M1 M2 ...
Page 140: ...General Outline ESIE10 01 1 134 Part 1 System Outline 3 1 1 4 5 1 36 30 Terminals M3 ...
Page 141: ...ESIE10 01 General Outline Part 1 System Outline 1 135 3 1 4 5 1 36 31 Terminals M5 MQ ...
Page 148: ...General Outline ESIE10 01 1 142 Part 1 System Outline 3 1 1 4 5 ...
Page 150: ...ESIE10 01 2 2 Part 2 Functional Description 3 1 2 5 ...
Page 170: ...The Digital Controller ESIE10 01 2 22 Part 2 Functional Description 3 1 2 4 5 ...
Page 200: ...Functional Control ESIE10 01 2 52 Part 2 Functional Description 3 1 2 4 5 ...
Page 202: ...ESIE10 01 3 2 Part 3 Troubleshooting 3 1 3 5 ...
Page 254: ...Alarms and Events ESIE10 01 3 54 Part 3 Troubleshooting 3 1 3 4 5 ...
Page 266: ...Controller Inputs and Outputs ESIE10 01 3 66 Part 3 Troubleshooting 3 1 3 4 5 ...
Page 280: ...ESIE10 01 4 2 Part 4 Commissioning and Test Run 3 1 4 5 ...
Page 286: ...Pre Test Run Checks ESIE10 01 4 8 Part 4 Commissioning and Test Run 3 1 4 5 ...
Page 289: ...ESIE10 01 Running Data Part 4 Commissioning and Test Run 4 11 3 4 5 1 ...
Page 290: ...Running Data ESIE10 01 4 12 Part 4 Commissioning and Test Run 3 1 4 5 ...