6 Preparation
Installation manual
10
EZESHP20 EZLSHP20AUAW1B
Exigo E1500 Trailer Refrigeration Unit
4P726857-1 – 2023.03
5.2
Combining units and options
INFORMATION
Certain options may NOT be available in your country.
a
b
d
e
c
a
Solar panel
b
Rear door switch
c
Fuel level probe
d
Pre-filter heater
e
Cold chain data logger
Solar panel
Solar panel and charge controller to ensure the efficiency of the 12V
battery and to save energy.
Rear door switch
Metallic IP grade switch to be connected with Exigo unit and
telematics to detect the opening of trailer doors.
The micro switch signal has a dual function. As soon as the cold
room door opens, it interrupts the thermoregulation mode and
switches on the internal lighting in the cold room.
Fuel level probe
Compact and robust advanced capacitance sensor for continuously
monitoring the fuel level in the tank.
Fuel pre-filter heater
Heater based on a PTC heating element controlled by bi-metallic
switch. The heating element is designed to create a small channel in
the filter head where diesel remains liquid instead of becoming gel at
low ambient temperatures.
Cold chain data logger
Temperature recorder that allows continuous temperature monitoring
and proof of compliance from origin to destination.
6
Preparation
6.1
To prepare the cold room
INFORMATION
The procedure described below for preparing the cold
room is only an example. The bodybuilder may opt for a
different fixing system, but it must be at least as safe or
safer.
INFORMATION
This manual only describes installation instructions specific
to this unit. For carrying out mechanical work on the cold
room and trailer, the instructions of the cold room/trailer
manufacturer must always be followed.
INFORMATION
Double loading doors are recommended for a cold room
trailer. These reduce the chances of someone getting
trapped in the cold room. An additional inspection door on
the side of the trailer reduces cold loss during any
inspection.
INFORMATION
The trailer and cold room structure must be evaluated by
the trailer/cold room manufacturer to determine its ability to
withstand the loads imposed by the unit over its service
life. See
23] for dimensions and
weight.
The structural integrity of the trailer/cold room is a
responsibility of the user. Daikin accepts no liability for the
trailer's or cold room's structural integrity.
The surfaces of the cold room that contact the unit's mounting pads
must be uni-planar to within 3 mm to prevent distortion of the unit
and/or cold room.
To ensure proper air seal, cold room surfaces that contact the
mounting gasket should not protrude more than 5 mm above the
plane defined by the mounting pad surfaces.
The evaporator fan grills must stay in place, even when air duct
collectors are mounted in the cold room.
1
Make a cutout (d) and 8 holes (c) in the front of the cold room.
(It is sufficient to make only one of the two central holes).
37
1704
175.2
32
889
889
32
1181
1101
918
117
143,2
c
c
c
c
c
c
a
b
d
c
c