9 Hand-over to the user
Installation manual
23
EZESHP20 EZLSHP20AUAW1B
Exigo E1500 Trailer Refrigeration Unit
4P726857-1 – 2023.03
WARNING
Do no operate the unit in road mode (with diesel engine
running) in confined spaces and areas where fumes from
the engine could become trapped and cause serious injury
or death.
In confined spaces, use the dedicated function on the HMI
to disable automatic road mode start-up.
WARNING
Keep your hands, clothing and tools clear of moving parts
such as fans and engine belt when the unit is working.
WARNING
When the unit is operating, a magnetic field is generated.
This can disturb the functioning of cardiac devices like
pacemakers and defibrillators. People who have such
devices implanted must stay clear of the working unit when
the service doors are opened.
1
Start up the unit in road mode. The fuel tank suction pipe is still
empty at this moment. Operate the hand pump (a) on the fuel
pre-filter to get the fuel (faster) to the fuel pump and the unit.
a
2
Check the correct functioning (cooling on the evaporator side)
of the unit.
3
Check that there are no fuel leaks between the fuel tank and
the unit.
4
Switch off the unit.
5
Start up the unit in standby mode.
6
Check the correct functioning (cooling on the evaporator side)
of the unit.
7
Manually start the defrost mode (see user manual).
8
Check that water drains properly through the collection drain
hoses onto the ground.
9
Check that no alarms occur on the user interface (see user
manual).
10
Switch off the unit.
DANGER: RISK OF BURNING/SCALDING
Allow the PM generator, the engine, the engine exhaust
and the engine- cooling system to cool down before
touching any of these parts.
9
Hand-over to the user
Once the test run is finished and the unit operates properly, make
sure the following is clear for the user:
▪ Make sure that the user has the printed documentation and ask
him/her to keep it for future reference. Inform the user that he can
find the complete documentation at the URL mentioned earlier in
this manual.
▪ Explain the user how to properly operate the system and what to
do in case of problems.
▪ Show the user what to do for the maintenance of the unit.
10
Disposal
The metal pallet on which the unit is fixed at delivery may be
returned to sender or recycled, whichever is the most cost- and
environment-friendly solution.
Wooden, plastic and polystyrene packing must be disposed of
according to the regulations in force in the country where the unit is
used.
NOTICE
Do NOT try to dismantle the system yourself: dismantling
of the system, treatment of the refrigerant, oil and other
parts MUST comply with applicable legislation.
Final disposal of the unit must be done by an authorized
area technical assistance service, that has proper training,
equipment and instructions for the dismantling. They are
also responsible for reuse, recycling and recovery.
CAUTION
There are potential environmental hazards involved in
dismantling the unit.
11
Technical data
▪ A
subset
of the latest technical data is available on the regional
Daikin website (publicly accessible).
▪ The
full set
of latest technical data is available on the Daikin
Business Portal (authentication required).
11.1
Wiring diagram
▪ A printed version of the declaration of conformity, the wiring- and
piping diagrams is included with the unit.
A printed version of the wiring- and piping diagrams is included with
the unit.
The unit is delivered fully wired from the factory. Therefore, the
wiring diagrams are not required during installation.
Wiring diagram legend
For applied parts and numbering, refer to the wiring diagram on the
unit. Part numbering is by Arabic numbers in ascending order for
each part and is represented in the overview below by "*" in the part
code.
Symbol
Meaning
Symbol Meaning
Circuit breaker
contact
Noise filter
3
MS
Compressor
Power supply plug
Connection
p
Pressure switch
Connector
Protective earth