8
|
Operation
Installer and user reference guide
29
FAA71+100BUV1B
Split system air conditioner
4P654517-1 – 2021.03
8 Operation
8.1 Operation range
Use the system in the following temperature and humidity ranges for safe and
effective operation.
For combination with R410A outdoor unit, refer to the following table:
Outdoor units
Cooling
Heating
RZQ200
Outdoor
temperature
–5~46°C DB
–15~15°C WB
Indoor
temperature
14~28°C WB
10~27°C DB
RZQG71~140
Outdoor
temperature
–15~50°C DB
–20~15.5°C WB
Indoor
temperature
12~28°C WB
10~27°C DB
RZQSG71~140
Outdoor
temperature
–15~46°C DB
–15~15.5°C WB
Indoor
temperature
14~28°C WB
10~27°C DB
Indoor humidity
≤80%
(a)
—
(a)
To avoid condensation and water dripping out of the unit. If the temperature or the
humidity is beyond these conditions, safety devices may be put in action and the air
conditioner may not operate.
For combination with R32 outdoor unit, refer to the following table:
Outdoor units
Cooling
Heating
RZAG71~140
Outdoor
temperature
–20~52°C DB
–20~24°C DB
–20~18°C WB
Indoor
temperature
17~38°C DB
12~28°C WB
10~27°C DB
RZASG71~140
Outdoor
temperature
–15~46°C DB
–15~21°C DB
–15~15.5°C WB
Indoor
temperature
20~38°C DB
14~28°C WB
10~27°C DB
100
Outdoor
temperature
–5~46°C DB
–15~21°C DB
–15~15.5°C WB
Indoor
temperature
20~38°C DB
14~28°C WB
10~27°C DB
250
Outdoor
temperature
-20~46°C DB
-20~15°C WB
Indoor
temperature
14~28°C WB
10~27°C DB