11. SPECIFICATIONS

INDOOR UNIT

FA71FVEK FA100FVEK FAY71FVE FAY100FVE

OUTDOOR UNIT

R71FUVAL R100FUVAL RY71FUVAL RY100FUVAL

RATED VOLTAGE

V

220

220

220

220

RATED FREQUENCY

Hz

60

60

60

60

COOLING

POWER INPUT RATING

kW

4.1

5.7

4.2

5.8

CURRENT INPUT RAT-
ING

A

19.3

26.6

19.7

26.7

CAPACITY

kW

6.7

9.5

6.7

9.0

kcal/h

5800

8200

5800

7700

HEATING

POWER INPUT RATING

kW

3.7

4.9

CURRENT INPUT RAT-
ING

A

17.4

22.6

CAPACITY

kW

8.5

11.8

kcal/h

7300

10100

WEIGHT OF INDOOR UNIT

kg

26

27

26

27

WEIGHT OF OUTDOOR UNIT

kg

87

117

91

120

REFRIGERANT

R22

R22

R22

R22

MASS OF REFRIGERANT CHARGE

kg

2.2

2.9

2.3

2.6

COUNTRY OF ORIGIN

Í

Í

indoor

JAPAN

JAPAN

JAPAN

JAPAN

outdoor

THAILAND

THAILAND

THAILAND

THAILAND

MANUFACTURER’S NAME

indoor

DAIKIN 

INDUSTRIES 

LTD.

DAIKIN 

INDUSTRIES 

LTD.

DAIKIN 

INDUSTRIES 

LTD.

DAIKIN 

INDUSTRIES 

LTD.

outdoor

DAIKIN 

INDUSTRIES 

(THAILAND)

LTD.

DAIKIN 

INDUSTRIES 

(THAILAND)

LTD.

DAIKIN 

INDUSTRIES 

(THAILAND)

LTD.

DAIKIN 

INDUSTRIES 

(THAILAND)

LTD.

01_EN_3P170549-3.fm  Page 11  Friday, December 9, 2005  11:45 AM

Summary of Contents for FAY71FVE

Page 1: ...ANDY PLACE FOR FUTURE REFERENCE LEA CUIDADOSAMENTE ESTAS INSTRUCCIONES ANTES DE INSTALAR GUARDE ESTE MANUAL EN UN LUGAR A MANO PARA LEER EN CASO DE TENER ALGUNA DUDA MODELS Wall mounted type FAY71FVE...

Page 2: ...ng the manual file it away for future reference Le agradecemos la compra de este acondicio nador de aire Daikin Lea cuidadosamente el manual de funciona miento antes de utilizar el acondicionador de a...

Page 3: ...4 2 TEST C hr hr TEST NOT AVAILABLE L H 2 10 11 3 1 4 5 6 7 8 14 15 16 17 18 19 20 21 22 12 9 13 R Y 71 b d f k e i h a j d f g e c R Y 100 C hr H 00_CV_3P170549 3 fm Page 2 Friday December 9 2005 1...

Page 4: ...SYSTEM This system provides two other control systems beside individual control one remote controller con trols one indoor unit system Confirm the following if your unit is of the following control s...

Page 5: ...r dealer When the air conditioner is to be installed in a small room it is necessary to take proper mea sures so that the amount of any leaked refriger ant does not exceed the limiting concentration e...

Page 6: ...wise injury may be caused Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit Leaves are a hotbed for small animals which can...

Page 7: ...result in a water leakage from the indoor unit Under such circumstances stop the operation of the air conditioner and then consult your dealer or our service station Refer to figure 1 on page 1 The il...

Page 8: ...planation all indications are shown on the display in figure 1 contrary to actual running situations 6 OPERATION PROCEDURE COOLING HEATING AUTOMATIC FAN AND PROGRAM DRY OPERATION OPERATION MODE SELEC...

Page 9: ...t AIR FLOW DIRECTION ADJUST There are 2 ways of adjusting the air discharge angle ADJUSTMENT A Up and down adjustment B Left and right direction A UP AND DOWN DIRECTION Press the AIR FLOW DIRECTION AD...

Page 10: ...dure from to once again When the timer is programmed to stop the system after 3 hours and start the system after 4 hours the system will stop after 3 hours and then 1 hour later the system will start...

Page 11: ...ush and neutral detergent Remove water and dry in the shade NOTE Do not wash the air conditioner with hot water of more than 50 C as doing so may result in discol oration and or deformation Do not exp...

Page 12: ...E AIR CONDITIONER II WHITE MIST COMES OUT OF A UNIT When humidity is high during cooling opera tion In oily or dusty places If the inside of an indoor unit is extremely contam inated the temperature d...

Page 13: ...lfunction occurs UNIT No C L H Check if no fuse has blown Turn off the power supply Check if the breaker is blown Turn the power on with the breaker switch in the off position Do not turn the power on...

Page 14: ...9 CURRENT INPUT RAT ING A 17 4 22 6 CAPACITY kW 8 5 11 8 kcal h 7300 10100 WEIGHT OF INDOOR UNIT kg 26 27 26 27 WEIGHT OF OUTDOOR UNIT kg 87 117 91 120 REFRIGERANT R22 R22 R22 R22 MASS OF REFRIGERANT...

Page 15: ...3P170549 3 EM95A057F 0602 HT 00_CV_3P170549 3 fm Page 4 Friday December 9 2005 1 46 PM...

Reviews: