48
English
INDOOR UNIT
FD
YM24PEVLK
FD
YM30PEVLK
FD
YM36PEVLK
FD
YM42PEVLK
OUTDOOR UNIT
R
Y24PEVLK
R
Y30PEVLK
R
Y36PEVLK
R
Y42PETLK
RA
TED V
O
LT
A
G
E
V
220
220
220
220
RA
TED FREQ
UENCY
Hz
60
60
60
60
COOLING(T1)
RA
TED PO
WER INPUT
kW
2.70
3.45
4.00
5.17
RA
TED CURRENT INPUT
A
13.0
16.5
19.0
16.2
CAP
A
CITY
kW
6.6
8.2
9.4
12.0
Btu/h
22500
28000
32000
41000
EER
(Btu/h)/W
8.34
8.12
8.00
7.93
COOLING(T3)
RA
TED PO
WER INPUT
kW
3.10
4.15
4.80
6.20
RA
TED CURRENT INPUT
A
15.0
19.5
22.0
18.6
CAP
A
CITY
kW
6.1
7.1
8.6
10.7
Btu/h
20800
23800
29300
36500
EER
(Btu/h)/W
6.71
5.73
6.10
5.89
HEA
TING
RA
TED PO
WER INPUT
kW
2.60
3.40
3.50
5.27
RA
TED CURRENT INPUT
A
12.5
16.0
16.0
17.1
CAP
A
CITY
kW
7.5
9.3
10.5
14.0
Btu/h
25600
31700
35800
48000
COP
W/W
2.88
2.74
3.00
2.66
REFRIGERANT
R22
R22
R22
R22
MASS OF REFRIGERANT CHARGE
kg
2.1
2.9
3.4
4.5
WEIGHT OF INDOOR UNIT
kg
37
37
57
57
WEIGHT OF OUTDOOR UNIT
kg
55
68
68
109
COUNTR
Y OF ORIGIN
MADE IN CHINA
INDOOR UNIT
FD
YM42PEVLK
FD
YM48PEVLK
FD
YM48PEVLK
OUTDOOR UNIT
R
Y42PEYLK
R
Y48PETLK
R
Y48PEYLK
RA
TED V
O
LT
A
G
E
V
380
220
380
RA
TED FREQ
UENCY
Hz
60
60
60
COOLING(T1)
RA
TED PO
WER INPUT
kW
5.17
5.79
5.79
RA
TED CURRENT INPUT
A
8.6
18.4
9.8
CAP
A
CITY
kW
12.0
13.2
13.2
Btu/h
41000
45000
45000
EER
(Btu/h)/W
7.93
7.77
7.77
COOLING(T3)
RA
TED PO
WER INPUT
kW
6.20
7.01
7.01
RA
TED CURRENT INPUT
A
10.3
21.4
11.9
CAP
A
CITY
kW
10.7
11.7
11.7
Btu/h
36500
40000
40000
EER
(Btu/h)/W
5.89
5.71
5.71
HEA
TING
RA
TED PO
WER INPUT
kW
5.27
5.90
5.90
RA
TED CURRENT INPUT
A
9.2
19.3
10.5
CAP
A
CITY
kW
14.0
16.0
16.0
Btu/h
48000
54600
54600
COP
W/W
2.66
2.71
2.71
REFRIGERANT
R22
R22
R22
MASS OF REFRIGERANT CHARGE
kg
4.6
4.4
4.4
WEIGHT OF INDOOR UNIT
kg
57
57
57
WEIGHT OF OUTDOOR UNIT
kg
109
109
109
COUNTR
Y OF ORIGIN
MADE IN CHINA