Installation manual
1
FDYP125~2 FDQ125~250B8V3B
Split System air conditioners
4PW23694-1A
C
ONTENTS
Page
Before installation.............................................................................. 1
Preparations before installation......................................................... 2
Indoor unit installation ....................................................................... 3
Refrigerant piping work ..................................................................... 3
Vacuum drying of installation ............................................................ 3
Drain piping work .............................................................................. 3
Test operation.................................................................................... 5
Internal wiring - parts table................................................................ 6
B
EFORE
INSTALLATION
■
Decide upon a line of transport.
■
Leave the unit inside its packaging while moving, until reaching
the installation site. Where unpacking is unavoidable, use a sling
of soft material or protective plates together with a rope when
lifting, to avoid damage or scratches to the unit.
■
Refer to the installation manual of the outdoor unit for items not
described in this manual.
■
Caution concerning refrigerant series R410A:
-
The connectable outdoor units must be designed exclusively
for R410A.
-
If outdoor units for R22, R407C are connected, the system
will not work properly.
Accessories
Check if the following accessories are included with your unit.
Installation manual, Operation manual
Note to the installer
■
Be sure to instruct the customer how to properly operate the
system and show him/her the attached operation manual.
■
Explain to the customer what system is installed on the site. Be
sure to fill out the appropriate installation specifications in the
chapter "What to do before operation" in the operation manual.
I
NSTALLATION
SITE
1.
Select an installation site where the following conditions are
fulfilled and that meets your customers approval.
■
Is the air conditioner installed at a well-ventilated place where
there are no obstacles around?
■
Do not install or use the air conditioner in the following places.
-
Filled with much mineral oil such as cutting oil;
-
Where there is much salt such as a beach area;
-
Where sulfured gas exists such as hot spring resorts;
-
Where there are considerable voltage fluctuations such as a
factory or plant;
-
Vehicles and vessels;
-
Where there is much spray of oil and vapour such as a
kitchen;
-
Where there are machines generating electromagnetic
waves;
-
Filled with acid and/or alkaline steam or vapour.
■
Pay attention to operating noise.
-
Select a place where the ceiling is strong enough to support
the unit and to prevent vibration and noise generation.
-
If abnormal noises occur, contact your dealer.
■
Where sufficient clearance for maintenance and service can be
ensured (Refer to
= service space). The power
supply intake (1), the drain connection (2), gas pipe (3) and
liquid pipe (4) connection should always be accessible for
maintenance and service.
■
Where piping between indoor and outdoor units is possible
within the allowable limit. (Refer to the installation manual for the
outdoor unit.)
■
Where there is no danger of fire due to leakage of flammable
gas. If the gas leaks out and stays around the air conditioner, a
fire may break out.
■
Ensure that water can not cause any damage to the location in
case it drips out of the unit (e.g. in case of a blocked drain pipe).
FDYP125B8V1
FDQ125B8V3B
FDYP200B8V1
FDQ200B8V3B
FDYP250B8V1
FDQ250B8V3B
Split System air conditioners
Installation manual
READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLATION.
KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE
REFERENCE.
IMPROPER INSTALLATION OR ATTACHMENT OF
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY
TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE
SPECIFICALLY DESIGNED FOR USE WITH THE
EQUIPMENT AND HAVE THEM INSTALLED BY A
PROFESSIONAL.
IF UNSURE OF INSTALLATION PROCEDURES OR USE,
ALWAYS CONTACT YOUR DAIKIN DEALER FOR
ADVICE AND INFORMATION.
Sp
lit S
yste
m a
ir c
ond
itio
ners
Eng
lish
Deu
tsc
h
Fra
nça
is
Ned
erla
nds
Esp
año
l
Ital
ian
o
∂
ÏÏË
ÓÈο
Por
tug
ues
Dan
sk
Insta
llati
on
ma
nua
l
Split
Sy
stem
air
con
ditio
ner
s
Insta
llatio
nsa
nleit
ung
Spl
it-B
aur
eihe
Klim
age
räte
Ma
nue
l d'in
stal
latio
n
Clim
atis
eur
s de
la s
érie
Sp
lit
Mo
nta
geh
and
leid
ing
Spli
t-sy
stee
m a
irco
ndit
ione
rs
Ma
nua
l de
ins
tala
ción
Aco
ndic
iona
dor
es d
e a
ire
ser
ie S
plit
Ma
nua
le d
'ins
talla
zion
e
Clim
atiz
zato
ri se
rie
Spli
t
EÁ¯
ÂÈÚ
›‰ÈÔ
ÂÁ
ηÙ
¿ÛÙ
·ÛË
˜
KÏÈÌ
·ÙÈÛ
ÙÈο
Sp
lit
Ma
nua
l de
ins
tala
ção
Apa
relh
os d
e a
r co
ndic
iona
do
da
sér
ie S
plit
Inst
alla
tion
sve
jled
ning
Klim
aan
lag i
op
delt
sys
tem
FD
Y12
5F7
V1
FD
Y20
0F7
V1
FD
Y25
0F7
V1
Sp
lit S
yste
m a
ir c
ond
itio
ners
INS
TAL
LAT
ION
MA
NU
AL
Eng
lish
Deu
tsc
h
Fra
nça
is
Ned
erla
nds
Esp
año
l
Ital
ian
o
∂
ÏÏË
ÓÈο
Por
tug
ues
Dan
sk
Insta
llatio
n m
anu
al
Split
Sy
stem
air
con
ditio
ner
s
Insta
llatio
nsa
nleit
ung
Split
-Ba
ure
ihe
Klim
age
räte
Ma
nue
l d'in
stall
atio
n
Clim
atis
eur
s de
la s
érie
Sp
lit
Mo
nta
geh
and
leid
ing
Spl
it-sy
stee
m a
irco
ndit
ione
rs
Ma
nua
l de
ins
tala
ción
Aco
ndic
iona
dor
es d
e a
ire
ser
ie S
plit
Ma
nua
le d
'ins
talla
zion
e
Clim
atiz
zato
ri se
rie
Spli
t
EÁ¯
ÂÈÚ
›‰ÈÔ
ÂÁ
ηÙ
¿ÛÙ
·ÛË
˜
KÏÈÌ
·ÙÈÛ
ÙÈο
Sp
lit
Ma
nua
l de
ins
tala
ção
Apa
relh
os d
e a
r co
ndic
iona
do d
a sé
rie
Spl
it
Inst
alla
tion
sve
jled
ning
Klim
aan
lag i
op
delt
sys
tem
FD
Y12
5F7
V1
FD
Y20
0F7
V1
FD
Y25
0F7
V1
OP
ER
ATIO
N M
AN
UA
L