background image

11

English

2

Keep holding the clips at the upper part of the 
suction grille and pull them to frontward.

3. Take out the air filter. 

Refer to the Clause 2 for “

HOW TO CLEAN THE 

AIR FILTER

”. (page 10)

4. Clean the suction grille.

Wash the suction grille with water or neutral 
detergent using a soft brush and then dewater it.

When the suction grille is extremely contaminated

Spray the detergent for a ventilating fans and 
ranges directly to the grille, and keep them under 
that condition for about 10 minutes.
After that, carefully wash the suction grille with 
water.

NOTE 

• Do not wash the suction grille with water of 

50°C or higher.
It may cause discoloration and deformation.

• When drying the suction grille, do not heat it 

with fire. It may cause burning.

• Do not use such as gasoline, benzine, thinner, 

polishing powder and liquid insecticide sold 
in the market.
It may cause discoloration and deformation.

5. Attach the air filter.

Refer to the Clause 4 for “

HOW TO CLEAN THE 

AIR FILTER

”. (page 10)

6. Attach the suction grille.

Attach the grille in the reverse order mentioned 
in the Clause 2.

Clip

Clips
FHQ35·50
FXHQ32

: 2 places

: 3 places

FHQ60·71·100·125·140
FXHQ63·100

Detergent

7. Close the suction grille.

Slide all the knobs in the reverse order men-
tioned in the Clause 1 and securely fix them.

HOW TO CLEAN AIR OUTLET, OUTSIDE 
PANEL, AND REMOTE CONTROLLER

Wipe them with a dry soft cloth.

When the stain cannot be wiped off, dip the cloth 
in the neutral detergent diluted with water and 
twist the cloth. After wiping off stain with this cloth, 
wipe them with dry cloth.

NOTE 

• Do not use such as gasoline, benzine, thinner, 

polishing powder and liquid insecticide sold 
in the market.
It may cause discoloration and deformation.

• Do not wash the filter with warm water of 50°C 

or higher. It may cause discoloration and 
deformation.

CLEANING BEFORE AND AFTER SEA-
SONAL USE

WHAT TO DO WHEN START UP AFTER A 
LONG STOP

Confirm the following

Check that the air inlet and outlet of indoor and 
outdoor unit are not blocked.
Remove any obstacle.
Obstacles decrease the fan speed, and cause 
performance decrease and breakage of the 
devices.

Clean the air filter

After cleaning the air filter, make sure to attach it.
(Refer to “

8. MAINTENANCE

” on page 9.)

For information on how to install, remove, or clean 
a optional sold air filter, refer to the user’s manual 
attached to the air filter.

Turn off the indication “

” or “Time to clean fil-

ter” displayed on the remote controller after turn-
ing on the power.
The indication can be turned off whether in oper-
ation or at stop.

<In case of BRC1E, BRC1D>

For details, refer to the operation manual 
attached to the remote controller. 

<In case of BRC1C>

Press FILTER SIGN RESET button.

Turn on the power circuit breaker at least 6 
hours before operation.

This is required in order to activate the air condi-
tioner smoothly, and to protect air conditioner.

The display on the remote controller will be shown 
when the power circuit breaker is turned on.

01_EN_3P303408-2N.fm  Page 11  Thursday, February 20, 2014  3:49 PM

Summary of Contents for FHQ35CAVEB

Page 1: ...ded type SPLIT SYSTEM VRV SYSTEM FHQ35CAVEB FXHQ32AVEB FHQ50CAVEB FXHQ63AVEB FHQ60CAVEB FXHQ100AVEB FHQ71CAVEB FHQ100CAVEB FHQ125CAVEB FHQ140CAVEB FHQ140CAVEA English Deutsch Fran ais Espa ol Italiano...

Page 2: ...interior consulte tambi n los manu ales de instrucciones suministrados con la unidad exterior y el mando a distancia Vi ringraziamo per aver acquistato questo prodotto Per garantire un corretto funzi...

Page 3: ...es debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalaciones especiali zadas para su re...

Page 4: ...es a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or modera...

Page 5: ...e amount of any leaked refrigerant does not exceed the concentration limit in the event of a leakage Otherwise this may lead to an accident due to oxygen depletion CAUTION Children should be watched s...

Page 6: ...the control box fan motor drain pump etc make sure to shut off all power sup ply for the air conditioner including both indoor and outdoor units When cleaning the heat exchanger make sure to remove th...

Page 7: ...remote controller con trols one indoor unit system Confirm the following if your unit is of the following control system type Group control system One remote controller controls up to 16 indoor units...

Page 8: ...ch mineral oil such as cutting oil b Where there is much salt such as a beach area c Where sulfured gas exists such as a hot spring resort d Where there are considerable voltage fluctua tions such as...

Page 9: ...nerally takes a longer time for indoor temper ature of the HEATING OPERATION to reach the set temperature compared to the COOLING OPERATION It is advisable to start operation in advance using the TIME...

Page 10: ...the PROGRAM DRY OPERATION When the indoor temperature is lowered airflow from the air condi tioner may stop When operating continuously at downward airflow direction air blows in the automatically se...

Page 11: ...n Your hand may get caught if you attempt to make adjustments while the horizontal blade is swing ing Stop the horizontal blade from swinging before trying to angle them Working while the blade is mov...

Page 12: ...ut your fingers or rods in the air inlet air outlet or horizontal blade The fan is rotat ing at high speed so you would get injured 8 MAINTENANCE FOR SERVICE PERSONNEL CAUTION Do not wash the air cond...

Page 13: ...r After the air filter is cleaned return the air filter to the original place as it was attached before 5 Close the suction grille Slide all the knobs in the reverse order men tioned in the Clause 1 a...

Page 14: ...ped off dip the cloth in the neutral detergent diluted with water and twist the cloth After wiping off stain with this cloth wipe them with dry cloth NOTE Do not use such as gasoline benzine thinner p...

Page 15: ...the power is supplied to the air conditioner Some models perform the following operation to protect the devices If the HEATING OPERATION is performed within 6 hours after the power is supplied to the...

Page 16: ...n speed changes Raise the set temperature After a while the fan speed changes IV THE AIRFLOW DIRECTION IS DIFFERENT FROM THE SETTING OR THE AIRFLOW DIRECTION IS DIFFERENT FROM THE DIS PLAY ON THE REMO...

Page 17: ...st absorbed by the unit blows out IX THE INDOOR UNITS GIVE OFF ODORS During operation The unit absorbs the smell of rooms furni ture cigarettes etc and then emits them If odor is a concern you can set...

Page 18: ...and discharge direction Check if the airflow direction is not proper Set to an appropriate temperature fan speed and discharge direction Check if the doors or the windows are open Shut doors or windo...

Page 19: ...1D Measure Notify your local dealer and inform malfunction code of the display 10 2 FXHQ Read the operation manual attached to the out door unit UNIT No C L H OPERATION lamp INSPECTION display MALFUNC...

Page 20: ...3P303408 2N EM12A007B 1404 HT 00_CV_3P303408 2N_01 fm Page 2 Monday February 17 2014 9 23 AM...

Reviews: