background image

15

English

2. If the air conditioner stops after operating the 

air conditioner.

Check if the air inlet or outlet of outdoor or 
indoor unit is blocked by obstacles. 
Remove the obstacle and make it well-venti-
lated.
The horizontal blades at the air outlet are 
closed while the indoor stops.

Check if the air filter is clogged.
Ask a qualified service person to clean the air 
filters. 
A decrease in the airflow volume of the air 
conditioner will result and the performance of 
the air conditioner will be degraded and power 
consumption will increase if the air filter is 
clogged with dust or dirt.
In addition, this may cause dew condensation 
at the air outlet.
(Refer to “

8. MAINTENANCE

” on page 9.)

3. The air conditioner operates but it does not 

sufficiently cool or heat.

Check if the air inlet or outlet of outdoor or 
indoor unit is blocked by obstacles. 
Remove the obstacle and make it well-venti-
lated.
The horizontal blades at the air outlet are 
closed while the unit stops.
Obstacles decrease the fan speed, and cause 
performance decrease and breakage when 
discharged air is suctioned.
They cause a waste of electricity, and that may 
stop the devices.

Check if the air filter is clogged.
Ask a qualified service person to clean the air 
filters.
A decrease in the airflow volume of the air 
conditioner will result and the performance of 
the air conditioner will be degraded and power 
consumption will increase if the air filter is 
clogged with dust or dirt.
In addition, this may cause dew condensation 
at the air outlet.
(Refer to “

8. MAINTENANCE

” on page 9.)

Check if the set temperature is not proper.
Set to an appropriate temperature, fan speed, 
and discharge direction.

Check if the FAN SPEED button is set to LOW 
SPEED.
Set to an appropriate temperature, fan speed, 
and discharge direction.

Check if the airflow direction is not proper. 
Set to an appropriate temperature, fan speed, 
and discharge direction.

Check if the doors or the windows are open.
Shut doors or windows to prevent wind from 
coming in.

Check if direct sunlight enters the room (when 
cooling).
Use curtains or blinds.

When there are too many inhabitants in the 
room (when cooling).

Check if the heat source of the room is exces-
sive (when cooling).

4. Operation was performed or stopped 

although the ON/OFF button was not 
pressed.

Are you sure that the ON/OFF timer operation 
is not used?
Turn off the ON/OFF timer.
Please refer to operation manual attached to 
the remote controller.

Are you sure that any remote control device is 
not connected?
Contact the central control room that directed 
the stop.

Are you sure that the display for centralized 
control is not lit?
Contact the central control room that directed 
the stop.

If the problem is not solved after checking the 
above points, please do not try to repair it 
yourself. 
In such cases, always ask your local dealer. 
At this time, please tell the symptom and 
model name (written on the model name 
plate).

If one of the following malfunctions occurs, take 
the measures shown below and contact your 
local dealer.

The air conditioner must be repaired by a qualified 
service person.

WARNING

When the air conditioner is malfunctioning 
(giving off a burning odor, etc.), turn off 
power to the air conditioner and contact your 
local dealer.

Continued operation under such circumstances 
may result in a failure, electric shocks or a fire. 
Contact your local dealer.

If a safety device such as a fuse, a power circuit 
breaker or an earth leakage breaker frequently 
actuates;

Measure:

Do not turn on the main power switch.

If the ON/OFF switch does not properly work;

Measure:

Turn off the main power switch.

If water leaks from the indoor unit.

Measure:

Stop the operation.

01_EN_3P303408-2N.fm  Page 15  Thursday, February 20, 2014  3:49 PM

Summary of Contents for FHQ35CAVEB

Page 1: ...ded type SPLIT SYSTEM VRV SYSTEM FHQ35CAVEB FXHQ32AVEB FHQ50CAVEB FXHQ63AVEB FHQ60CAVEB FXHQ100AVEB FHQ71CAVEB FHQ100CAVEB FHQ125CAVEB FHQ140CAVEB FHQ140CAVEA English Deutsch Fran ais Espa ol Italiano...

Page 2: ...interior consulte tambi n los manu ales de instrucciones suministrados con la unidad exterior y el mando a distancia Vi ringraziamo per aver acquistato questo prodotto Per garantire un corretto funzi...

Page 3: ...es debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalaciones especiali zadas para su re...

Page 4: ...es a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or modera...

Page 5: ...e amount of any leaked refrigerant does not exceed the concentration limit in the event of a leakage Otherwise this may lead to an accident due to oxygen depletion CAUTION Children should be watched s...

Page 6: ...the control box fan motor drain pump etc make sure to shut off all power sup ply for the air conditioner including both indoor and outdoor units When cleaning the heat exchanger make sure to remove th...

Page 7: ...remote controller con trols one indoor unit system Confirm the following if your unit is of the following control system type Group control system One remote controller controls up to 16 indoor units...

Page 8: ...ch mineral oil such as cutting oil b Where there is much salt such as a beach area c Where sulfured gas exists such as a hot spring resort d Where there are considerable voltage fluctua tions such as...

Page 9: ...nerally takes a longer time for indoor temper ature of the HEATING OPERATION to reach the set temperature compared to the COOLING OPERATION It is advisable to start operation in advance using the TIME...

Page 10: ...the PROGRAM DRY OPERATION When the indoor temperature is lowered airflow from the air condi tioner may stop When operating continuously at downward airflow direction air blows in the automatically se...

Page 11: ...n Your hand may get caught if you attempt to make adjustments while the horizontal blade is swing ing Stop the horizontal blade from swinging before trying to angle them Working while the blade is mov...

Page 12: ...ut your fingers or rods in the air inlet air outlet or horizontal blade The fan is rotat ing at high speed so you would get injured 8 MAINTENANCE FOR SERVICE PERSONNEL CAUTION Do not wash the air cond...

Page 13: ...r After the air filter is cleaned return the air filter to the original place as it was attached before 5 Close the suction grille Slide all the knobs in the reverse order men tioned in the Clause 1 a...

Page 14: ...ped off dip the cloth in the neutral detergent diluted with water and twist the cloth After wiping off stain with this cloth wipe them with dry cloth NOTE Do not use such as gasoline benzine thinner p...

Page 15: ...the power is supplied to the air conditioner Some models perform the following operation to protect the devices If the HEATING OPERATION is performed within 6 hours after the power is supplied to the...

Page 16: ...n speed changes Raise the set temperature After a while the fan speed changes IV THE AIRFLOW DIRECTION IS DIFFERENT FROM THE SETTING OR THE AIRFLOW DIRECTION IS DIFFERENT FROM THE DIS PLAY ON THE REMO...

Page 17: ...st absorbed by the unit blows out IX THE INDOOR UNITS GIVE OFF ODORS During operation The unit absorbs the smell of rooms furni ture cigarettes etc and then emits them If odor is a concern you can set...

Page 18: ...and discharge direction Check if the airflow direction is not proper Set to an appropriate temperature fan speed and discharge direction Check if the doors or the windows are open Shut doors or windo...

Page 19: ...1D Measure Notify your local dealer and inform malfunction code of the display 10 2 FXHQ Read the operation manual attached to the out door unit UNIT No C L H OPERATION lamp INSPECTION display MALFUNC...

Page 20: ...3P303408 2N EM12A007B 1404 HT 00_CV_3P303408 2N_01 fm Page 2 Monday February 17 2014 9 23 AM...

Reviews: