background image

ISO14001 assures an effective environmental 
management system in order to help protect 
human•health•and the environment from the potential 
impact of our activities, products and services and to 
assist in maintaining and improving the quality of 
the•environment.

Daikin Europe N.V. is approved by LRQA for its Quality 
Management System in accordance with the ISO9001 
standard. ISO9001 pertains to quality assurance regarding 
design, development, manufacturing as well as to services 
related to the product.

Daikin units comply with the European
regulations that guarantee the safety of
the product.

Zandvoordestraat 300
B-8400 Ostend - Belgium
www.daikineurope.com

EED

E06-1/3 • 

06/2006

Pr

e

p

ar

e

d

 in

 Be

lg

iu

m b

y La

nn

o

o

The present publication is drawn up by way of 
information only and does not constitute an offer 
binding upon Daikin Europe N.V.. Daikin Europe N.V. 
has compiled the content of this publication to the 
best of its knowledge. No express or implied warranty 
is given for the completeness, accuracy, reliability or 
fitness for particular purpose of its content and the 
products and services presented therein. Specifications 
are subject to change without prior notice. Daikin 
Europe N.V. explicitly rejects any liability for any direct 
or indirect damage, In the broadest sense, arising from 
or related to the use and/or interpretation of this 
publication. All content is copyrighted by Daikin 
Europe N.V..

ÉEEDE06-1/3ÇËÍ

Split - Sky Air

Daikin Europe N.V. is participating in the 
EUROVENT Certification Programme. 
Products are as listed in the EUROVENT 
Directory of Certified Products. 

Summary of Contents for FLXS-BAVMB

Page 1: ...technical data FLXS BAVMB Flexi Type Inverter Controlled Unit air conditioning systems Split Sky Air ...

Page 2: ... only 3 Technical Specifications 3 Electrical Specifications 4 3 Options 5 4 Control systems 6 5 Dimensional drawing centre of gravity 7 Dimensional drawing 7 Centre of gravity 8 6 Piping diagram 9 7 Wiring diagram 10 Wiring diagram 10 8 Sound data 11 Sound level data 11 Sound pressure spectrum 12 9 Installation 14 Installation method 14 ...

Page 3: ...and pollen and deactivates bacteria and viruses Washable front panel Indoor unit silent operation Silent button on the remote control lowers the operation sound of the indoor unit by 3dB A only if connected to a DC inverter controlled outdoor unit Easy to install Up to 4 indoor units can be connected to 1 Multi outdoor unit All indoor units are individually controllable with remote control and do ...

Page 4: ...11 40 12 00 Medium m min 6 80 7 60 10 00 10 70 Low m min 6 00 6 60 8 50 9 30 Silent Operation m min 5 2 5 6 7 6 8 3 Heating High m min 9 20 9 80 12 1 12 80 Medium m min 8 30 8 90 9 8 10 60 Low m min 7 40 8 00 7 5 8 40 Silent Operation m min 6 6 7 2 6 8 7 5 Fan Motor Quantity 1 1 1 1 Model KFP 220 34 4A Number of steps 5 steps silent and auto Motor Speed cooling High rpm 820 920 1380 1380 Medium rp...

Page 5: ...antity 1 1 1 1 Item Side cover Quantity 2 2 2 2 Item Binding band Quantity 4 4 4 4 Item Photocatalytic deodorizing filter Quantity 1 1 1 1 Item Extension auxiliary pipe Extension auxiliary pipe Quantity 2 2 Notes Sound values are measured in an anechoic room Sound pressure level is a relative value depending on the distance and acoustic environment For more details please refer to sound level draw...

Page 6: ... Unified ON OFF control DCS301B51 Schedule timer DST301B51 Interface adapter 3 KRP928A2S Photocatalytic deodorising filter with frame KAZ917A41 Photocatalytic deodorising filter without frame KAZ917A42 Air purification filter with frame KAF925B41 Air purification filter without frame KAF925B42 Anti theft protection for remote control 1 Wiring adapter is also required for each indoor unit 2 Wiring ...

Page 7: ...ERFUL button for POWERFUL operation 5 TEMPERATURE adjustment buttons It changes the temperature setting 6 ON OFF button Press this button once to start operation Press once again to stop it 7 MODE selector button It selects the operation mode Auto Dry I Cool u Heat w Fan B 8 OUTDOOR UNIT SILENT button SILENT operation 9 FAN setting button It selects the air flow rate setting 10 SWING button 11 ON ...

Page 8: ...7 FLX K S60B Floor level installation Location of wall holes Room temp thermistor Operation switch space for performance Heating 3D033694B FLK XS25 35 50 60B unit mm Rear Right The mark Y shows piping direction Signal receiver Under Cleaning indicator lamp Front panel fixing screws Timer indicator lamp Operation indicator lamp Signal transmitter FLX ARC433A5 FLK ARC433A6 Infrared remote control Up...

Page 9: ... Indoor Units R410A FLXS BAVMB 5 Split Sky Air Indoor Units 8 5 Dimensional drawing centre of gravity 5 2 Centre of gravity 4D027653C FLK XS B ...

Page 10: ...iagram 4D034012B FLK XS25 35 50 60B Indoor unit Heat exchanger Sirocco fan Fan motor Field piping 6 4Cut Field piping ACut Refrigerant flow Thermistor on heat exchanger Cooling Heating A B C FLX K S25B J 9 5 J 9 5 J 6 4 FLX K S35B FLX K S50B J 12 7 J 12 7 J 9 5 FLX K S60B ...

Page 11: ...eration will restart automatically when the main power supply is turned off and then turned on again C70 Running capacitor FU Fuse H1P H3P Pilot lamp M1F Fan motor M1S Swing motor PCB1 PCB4 Printed circuit board R1T R2T Thermistor S6 S37 X11A X21A Connector S1W Operation switch SW7 X1M Terminal strip R Protective earth Signal receiver Infrared remote control Transmission circuit ...

Page 12: ... 31 28 53 FLKS35B 38 32 29 54 FLKS50B 47 39 36 63 FLKS60B 48 41 39 64 Heat pump Model Sound pressure level Sound power level Cooling Heating 230V 50Hz Measuring location Cooling Heating H L SL FLXS25B 37 37 31 31 28 29 53 FLXS35B 38 39 32 33 29 30 54 FLXS50B 47 46 39 35 36 33 63 FLXS60B 48 47 41 37 39 34 64 63 Sound power levels were not available at time of publication Location of microphone Loca...

Page 13: ...ured in an anechoic chamber 2 Operation sound differs with operation and ambient conditions Legend 50 60Hz 220 240 220 230V H 50 60Hz 220 240 220 230V L 3D035247A Octave band sound pressure level dB 0dB 0 0002 µ bar Octave band center frequency Hz FLXS50B Cooling approximate threshold hearing for continuous noise NOTES 1 Operation sound is measured in an anechoic chamber 2 Operation sound differs ...

Page 14: ...ured in an anechoic chamber 2 Operation sound differs with operation and ambient conditions Legend 50 60Hz 220 240 220 230V H 50 60Hz 220 240 220 230V L 3D035247A Octave band sound pressure level dB 0dB 0 0002 µ bar Octave band center frequency Hz FLXS50B Heating approximate threshold hearing for continuous noise NOTES 1 Operation sound is measured in an anechoic chamber 2 Operation sound differs ...

Page 15: ...Photocatalytic deodorising filter j C Air purification filter j D Infrared remote control Before screwing the remote control holder to the wall make sure that control signals are properly received by indoor unit Space for installation work Min 200mm Air filters j E Remote control holder There should be no space between ceiling and the unit Space for installation work Min 200mm Space for installati...

Page 16: ...65 mm Rear side drain hose hole J40 mm Ceiling Drain hose Wall Right side piping hole J80 mm Wall Wall Liquid pipe Floor Gas pipe Floor Drain pipe Wall 1 Determine the position of the feed through hole so that the local piping is placed in a downward sloping direction 1 More than 170 35 40 40 55 30 97 48 102 26 150 Wall 55 40 1 050 800 162 255 490 Floor Rear side piping hole J80 mm Connection posi...

Page 17: ...in Belgium by Lannoo The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N V Daikin Europe N V has compiled the content of this publication to the best of its knowledge No express or implied warranty is given for the completeness accuracy reliability or fitness for particular purpose of its content and the products and services...

Reviews: