Si01-406
Specifications
Specifications
9
The data on the conditions (AS/NZS3823.1) :
(Conditions)
(Rated)
FTY25CVMA
FTY35CVMA
Cooling
Heating
Cooling
Heating
Capacity
kW
2.5
3.4
3.5
4.2
Running Current
A
5.1
5.6
7.4
7.3
Power Consumption
W
960
1,090
1,485
1,500
COP
W/W
2.60
3.12
2.36
2.80
Standard
Cooling
Heating
Piping Length
Power Supply
AS/NZS3823.1
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB/24°CWB
Indoor ; 20°CDB
Outdoor ; 7°CDB/6°CWB
7.5m
50Hz 230V
Summary of Contents for FT25CV1A