background image

Accessories ® ~ ® 

ITEM 

QTY. 

Remarks 

ITEM 

QTY. 

Remarks 

®  Mountina plate 

®  Remote controller holder fixina screw (M3 x 20L 

@  Mountina elate fixina screw (M4 x 25L) 

6/7" 

CO  4-Core wire (3. 7M) 

©  Wireless Remote Controller 

(M)  Tiewrap 

@  Dry battery  (AAA) 

®  Accessory filter 

112· 

®  Indoor Unit Fixina Screw (M4 x 12U 

®  Gas pipe {3.0M) 

®  Operation  Installation Manual 

1+1 

(9)  Liquid pipe (3.0M) 

@  E-Waste (Guideline) 

®  Drain socket 

®  Product warranty 

®  Heat insulation tape 

Q)  Remote controller holder 

©  Wi-Fi manual 

'O' Applicable for all models  '*'Applicable onlv  for  selected models.  ,.,,, Quantitv mav varv model to model. 

Note: The accessories parts included with the unit displayed on the packing case name plate/ Label of indoor and outdoor packing case 

Table No.1 

Precautions for Selecting a Location 

• Before choosing the installation site, obtain user approval.

®l•i•ii

1

1,lle

The indoor unit should be positioned in a place where: 

1)  the restrictions on the installation requirements specified 

in 

"Indoor/Outdoor Installation Diagram" 

are met, 

2)  both the air inlet and air outlet are unobstructed, 
3) the unit is not exposed to direct sunlight, 

4) the unit is away from sources of heat or steam, 
5)  there is no source of machine oil vapour 

(this may shorten the indoor unit service life), 

6) cool air is circulated throughout the room, 
7) the unit is away from electronic ignition type 

fluorescent lamps (inverter or rapid start type) as they 

may affect the remote controller  range, 

8) the unit is at least 1 m away from any television or radio set 

(the unit may cause interference with the picture or sound), 

9)  the unit can be installed at the recommended height (1.8m), 

10)  no laundry equipment is nearby. 

•fflGi•l•li

1

1,114

The outdoor unit should be positioned in a place where: 

1)  the restrictions on the installation requirements specified 

in 

"Indoor/Outdoor Installation Diagram" 

are met, 

2)  drain  water  causes no trouble or problem in particular, 

3)  both air inlet and outlet have clear paths of air 

(they should be free of snow in snowy districts), 

4)  the unit is in a clear path of air but not directly exposed 

to rain, strong winds, or direct sunlight, 

5)  there is no fear of inflammable gas leakage, 
6)  the unit is not  directly exposed to salt, sulfidized 

gases, or machine oil vapour (these may shorten the 

service life of the outdoor unit), 

7)  operating sound or hot airflow does not cause trouble 

to neighbours, 

8)  the unit is at least 3m away from any television or 

radio antenna. 

Outdoor Unit Installation Space Requirements 

� CAUTION-------------

When carrying the outdoor unit during installation, wear gloves to avoid injury. 

• Position the unit on a horizontal surface. 

Any tilt in the unit (front to back, right to left) should be 3

° 

or less to the horizontal. 

• Where a wall or other obstacle is in the path of the outdoor unit's 

intake or exhaust airflow, follow the installation space requirements below. 

• For any of the below installation patterns, the wall height on the 

outlet side should be 1200mm or less. 

Wall facing one side 

I

Walls facing two sides 

I

More than 100 

-�-�-

� 

Viewed from 

the front 

Viewed from 

the side 

Walls facing three sides 

I

-

More than 350 

1200 

or less 

�___1.__ 

More 

1

� 

More  than 351_ 

../J-

than 1oo 

�  -

c)f 

.. 

•"00 

More than 350 

More than 50 

More than 50 

Side view 

Top view 

Top view 

unit: mm 

Summary of Contents for FTHT35UV16W

Page 1: ...DAIKIN 3P665364 2T M21P077C DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL l Ji MODELS FTHT35UV16W FTHT50UV16V FTHT60UV16U FTHP50UV16U 3P665364 2T M21P077C...

Page 2: ...quality and or longevity of the object concerned Do not expose plants or animals directly to the airflow from the unit as this may cause adverse effects Do not place appliances that produce naked flam...

Page 3: ...ives signals from the remote controller When the unit receives a signal you will hear a beep sound Case Sound type Operation start beep beep Settings changed beep Operation stop long beep 12 Inverter...

Page 4: ...ONO button ECONO operation 10 COANDA button COANDA operation 11 TIMER CANCEL button Cancels the timer setting 12 ONTIMER button 13 OFFTIMER button 14 GOOD SLEEP DISPLAYbutton 15 DEW CLEAN button NOTE...

Page 5: ...The maximum transmission distance is about 7m To attach the accessory filters Set the accessory filters under the tabs of the filter frame on the indoor unit Filter type Micro filter PM2 5 When attac...

Page 6: ...erature will be 24 C Cool If set temperature 24 c Default set temperature will remain same as set prior to remote switched OFF Note Whenever AC is switched OFF in dry mode and is switched ON from remo...

Page 7: ...re starting the operation press t FANJ to set to Auto 2 Press MooE to select the DRY or COOL operation 3 Press t1 Air starts circulating about 1 minute after the operation is started However if the PO...

Page 8: ...ouvres are in auto swing mode 1 Press c sw aj and l G when the flap or louvres have reached the desired position In the 3 D airflow the flap and louvres move in turn ii or e disappears from the LCD No...

Page 9: ...el POWERFUL operation POWERFUL 2 Press agam disappears from the LCD NOTE Notes on COANDA operation The flap position will change preventing air from blowing directly on the occupants of the room If th...

Page 10: ...Set temperature does not display when the unit is in DRY operation or FAN operation Inverter output and set temperature may not display depending on the operation mode that is active The display turn...

Page 11: ...set the timer again After a circuit breaker has turned off After a power failure After replacing batteries in the remote controller Notes on ECONO operation ECONO operation can only be set when the un...

Page 12: ...s button Dry mode OFF Cooling operation To cancel DEW CLEAN operation Turn OFF the machine from Remote Controller Wi Fi Control NOTE Note on LED 7 Segment Brightness Control Ld indicates for the brigh...

Page 13: ...shaft on one side Disconnect the front panel shaft on the other side in the same manner You can also remove the front panel by pushing it open until the front panel shaft is disconnected 3 Clean the...

Page 14: ...e off easily wash them with neutral detergent thinned with lukewarm water then dry them up in the shade Be sure to remove the accessory filter optional part It is recommendedto clean the air filters e...

Page 15: ...ilter contact the service shop where you bought the air conditioner Dispose of the old filter as non flammable waste Dispose of the old filter frame in accordance with your local waste sorting procedu...

Page 16: ...efrosting operation hot air does not flow out of the indoor unit The flap does not start swinging The air conditioner is adjusting the position of the flap The flap will start immediately moving soon...

Page 17: ...a repair person Case Explanation The air conditioner does not Has a circuit breaker turned off or a fuse blown operate Is it a power failure OPERATION lamp is off Are batteries set in the remote contr...

Page 18: ...air conditioner automatically resumes operation in about 3 minutes You should just wait for a while If there is a risk lightning could strike in the neighbourhood stop operation and turn off the circu...

Page 19: ...CIRCUIT BOARD FAULT E5 OL STARTED E6 FAULTY COMPRESSOR START UP E7 DC FAN MOTOR FAULT EB OVERCURRENT INPUT F3 HIGH TEMPERATURE DISCHARGE PIPE CONTROL F6 HIGH PRESSURE CONTROL IN COOLING OUTDOOR UNIT H...

Page 20: ......

Page 21: ...installed securely Fall vibration noise No refrigerant gas leaks Incomplete cooling function Refrigerant gas and liquid pipes and indoor drain hose Water leakage extension are thermally insulated Dra...

Page 22: ...as stopvalve sservice port thenfullyopenliquidand gas stopvalves Do not attempt to turn valve rod beyond its stop 8 Tighten valve caps and service port caps for the liquid and gas stop valves with a t...

Page 23: ...ue 32 7 39 9N m 21 6 27 4N m O D 9 5mm 333 407 kgf cm 220 280 kgf cm Gas side I 0 D 12 7mm 49 5 60 3N m 48 1 59 7N m 505 615 kgf cm O D 15 9mm 61 8 75 4N m 490 61O kgf cm 10 8 14 7N m 110 150 kgf cm 6...

Page 24: ...s I When there is no work space because the unit is close to ceiling CAUTION 1 Push up Be sure to wear protection gloves Place both hands under the centre of the front grille and while pushing up pull...

Page 25: ...length is 3m in order to avoid noise from the outdoor unit and vibration Mechanical noise and vibration may occur depending on how the unit is installed and the environment in which it is used Dimensi...

Page 26: ...pipe cover Slit 1111q11111J Slit Vinyl tape This illustration shows the case of the left rear piping Sectional view wire Insulation tape Ventilation hose n tape Wrap the heat insulation tape around al...

Page 27: ...the unit it WARNING ____________________________________1_a1J_1 _N_ _ 4 Use a stabiliser if required by the voltage supply condition Do not use tapped wires extension cords or starburst connections as...

Page 28: ...ndoor unit to the A mounting plate with the E indoor unit fixing screws M4 x 12L 10 Caulk thegap between the pipe and the front grillewith putty 11 After completing refrigerant piping wiring and drain...

Page 29: ...5 885 116 5 116 5 906 127 127 5 Drain hose position Place the pipe port cover in this pocket Liquid pipe end Unit size available on name plate Table No 2 Through the wall hole j 6Smm t 1o 1100 610 Liq...

Page 30: ...he unit may cause interference with the picture or sound 9 the unit can be installed at the recommended height 1 8m 10 no laundry equipment is nearby fflGi l li11 114 The outdoor unit should be positi...

Page 31: ...nt gas leaks during installation ventilate the area immediately 0 Toxic gas may be produced if the refrigerant comes into contact with fire After completing installation check for refrigerant gas leak...

Page 32: ...3P665364 2T M21P076C DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL r MODELS FTHT35UV16W FTHT50UV16V FTHT60UV16U FTHP50UV16U J o I P 8 1 E C JNVERTER 3P665364 2T M21P076C...

Reviews: