DAMA-SM-21-001
Specification Data
Specifications
17
1) ALL UNITS ARE BEING TESTED ACCORDING TO AHRI 210/240 STANDARD.
2) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
MODEL
INDOOR UNIT
FTK18A
FTK24A
OUTDOOR UNIT
RK18A
RK24A
Rated Capacity (Min. ~ Max.)
kW
5.28 (1.60 - 5.86)
6.21 (1.60 - 7.03)
Btu/h
18000 (5500 - 20000)
21200 (5500 - 24000)
Moisture Removal
gal/h
0.41
0.67
Rated Running Current
A
6.39
7.70
Rated Power Consumption
W
1440
1738
EER
Btu/h/W
12.5
12.2
SEER
18.5
19.0
Power Factor (Rated)
N/A
Piping
Connections
Liquid
inch (mm)
1/4” (6.35)
Gas
inch (mm)
1/2” (12.70)
5/8” (15.88)
Refrigerant
Type
R410A
Charge
lbs (kg)
3.20 (1.45)
3.86 (1.75)
Max. Interunit Piping Length
ft (m)
98-1/2 (30)
Max. Interunit Height Difference
ft (m)
65-5/8 (20)
Chargeless
ft (m)
32-13/16 (10)
Amount of Additional Charge of Refrigerant
oz/ft (g/m)
0.21 (20)
INDOOR UNIT
FTK18A
FTK24A
Front Panel Colour
WHITE
Airflow Rate
Turbo
CFM
754
High
CFM
716
Medium
CFM
605
Low
CFM
467
Quiet
CFM
395
Sound Pressure Level (H/M/L/Q)
dBA
49/44/38/33
53/45/39/34
Fan
Type
CROSS FLOW
Drive
DIRECT
Speed
3 STEPS, QUIET, AUTO, TURBO
Fan Motor
Type
DIRECT CURRENT
Motor Output
W
35
Running Current (Rated)
A
0.145
Power Consumption (Rated)
W
47
Air Direction Control
UP, DOWN, LEFT, RIGHT
Air Filter
CATECHIN
Dimensions (H X W X D)
inch (mm)
11-11/16 X 39-1/2 X 11-1/3 (297 X 1005 X 288)
Packaged Dimensions (H X W X D)
inch (mm)
14-1/4 X 42-1/4 X 14-1/8 (362 X 1073 X 358)
Weight
lbs (kg)
31 (14)
Gross Weight
lbs (kg)
38 (17)
Condensate Drain Size
in. (mm)
3/4 (19.00)
OUTDOOR UNIT
RK18A
RK24A
Casing Colour
IVORY WHITE
Airflow Rate
High
CFM
2005
1908
Sound Pressure Level
dBA
54
55
Fan
Type
PROPELLER
Drive
DIRECT
Fan Motor
Type
DIRECT CURRENT
Index of protection (IP)
23
Insulation Grade
E
Running Current (Rated)
A
0.99
1.00
Power Consumption (Rated)
W
81
86
Motor Output
W
128
Poles
8
Compressor
Type
HERMETIC SWING
Model
D1C128S8P20-PN
Oil type
DAPHNE FVC50K
Oil amount
oz (cm
3
)
21.5 (650)
Running Current (Rated)
A
5.255
6.555
Power Consumption (Rated)
W
1312
1605
Heat Exchanger Type
FIN TUBE
Starting Current
A
7.33
11.00
Dimensions (H X W X D)
inch (mm)
27-13/32 x 36-5/8 x 13-13/16 (696 X 930 X 351)
Packaged Dimensions (H X W X D)
inch (mm)
29-7/8 x 42-3/8 x 18-7/8 (760 X 1075 X 480)
Weight
lbs (kg)
99 (45)
106 (48)
Gross Weight
lbs (kg)
108 (49)
115 (52)
Drawing No.
3D128372
3D128372
Document No. (Set)
3D128372
3D128372
COOLING
INDOOR: 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB)
OUTDOOR: 95°FDB (35°CDB)