DAMA-SM-21-001
Specification Data
Specifications
19
1) ALL UNITS ARE BEING TESTED ACCORDING TO AHRI 210/240 STANDARD.
2) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
MODEL
INDOOR UNIT
FTX12A
OUTDOOR UNIT
RX12A
Cooling
Heating
Rated Capacity (Min. ~ Max.)
kW
3.20 (1.30 - 3.90)
3.96 (1.30 - 4.80)
Btu/h
10900 (4400 - 13300)
13500 (4400 - 16400)
Moisture Removal
gal/h
0.19
Rated Running Current
A
3.99
4.70
Rated Power Consumption
W
872
1038
EER
Btu/h/W
12.5
N/A
SEER
19.0
N/A
COP
W/W
N/A
3.80
HSPF
N/A
10.0
Power Factor (Rated)
N/A
Piping
Connections
Liquid
inch (mm)
1/4” (6.35)
Gas
inch (mm)
3/8” (9.52)
Refrigerant
Type
R410A
Charge
lbs (kg)
2.09 (0.95)
Max. Interunit Piping Length
ft (m)
65-5/8 (20)
Max. Interunit Height Difference
ft (m)
49-1/4 (15)
Chargeless
ft (m)
32-13/16 (10)
Amount of Additional Charge of Refrigerant
oz/ft (g/m)
0.21 (20)
INDOOR UNIT
FTX12A
Front Panel Colour
WHITE
Airflow Rate
Turbo
CFM
473
High
CFM
436
412
Medium
CFM
316
Low
CFM
247
Quiet
CFM
210
Sound Pressure Level (H/M/L/Q)
dBA
45/37/31/26
45/37/30/26
Fan
Type
CROSS FLOW
Drive
DIRECT
Speed
3 STEPS, QUIET, AUTO, TURBO
Fan Motor
Type
DIRECT CURRENT
Motor Output
W
38
Running Current (Rated)
A
0.17
Power Consumption (Rated)
W
53
Air Direction Control
UP, DOWN, LEFT, RIGHT
Air Filter
CATECHIN
Dimensions (H X W X D)
inch (mm)
11-1/3 X 30-29/32 X 9-27/32 (288 X 785 X 250)
Packaged Dimensions (H X W X D)
inch (mm)
13-7/8 X 32-3/4 X 12-3/8 (350 X 830 X 314)
Weight
lbs (kg)
22 (10)
Gross Weight
lbs (kg)
27 (12)
Condensate Drain Size
in. (mm)
3/4 (19.00)
OUTDOOR UNIT
RX12A
Casing Colour
IVORY WHITE
Airflow Rate
High
CFM
1051
966
Sound Pressure Level
dBA
49
Fan
Type
PROPELLER
Drive
DIRECT
Fan Motor
Type
DIRECT CURRENT
Index of protection (IP)
24
Insulation Grade
E
Running Current (Rated)
A
0.47
Power Consumption (Rated)
W
43
36
Motor Output
W
41
Poles
8
Compressor
Type
HERMETIC SWING
Model
M5SLY10/15FR-1
Oil type
DAPHNE FVC50K
Oil amount
oz (cm
3
)
12.4 (375)
Running Current (Rated)
A
3.35
4.06
Power Consumption (Rated)
W
776
949
Heat Exchanger Type
FIN TUBE
Starting Current
A
6.06
Dimensions (H X W X D)
inch (mm)
21-11/16 X 26-1/2 X 11-3/16 (550 X 675 X 284)
Packaged Dimensions (H X W X D)
inch (mm)
24-1/64 X 31-3/8 X 15-1/8 (610 X 801 X 384)
Weight
lbs (kg)
64 (29)
Gross Weight
lbs (kg)
71 (32)
Drawing No.
3D128372
3D128372
Document No. (Set)
3D128372
3D128372
COOLING
HEATING
INDOOR: 80°FDB (26.7°CDB) / 67°FWB (19.4°CWB)
INDOOR: 70°FDB (21.1°CDB)
OUTDOOR: 95°FDB (35°CDB)
OUTDOOR: 47°FDB (8.3°CDB) / 43°FWB (6.1°CWB)
Summary of Contents for FTK Series
Page 2: ......