DAMA-SM-21-001
Main Functions
Functions and Control
25
The following drawing shows a schematic view of the inverter principle:
Inverter Features
The inverter provides the following features:
The regulating capacity can be changed according to the changes in the outdoor
temperature and cooling load.
Quick cooling
The rotation speed of the compressor is increased when starting the cooling.
This enables to reach the set temperature quickly.
Comfortable air conditioning
A fine adjustment is integrated to keep the room temperature constant.
Energy saving cooling
Once the set temperature is reached, the energy saving operation enables to maintain the
room temperature at low power.
Frequency Limits
The following functions regulate the minimum and maximum frequency:
Compressor protection function. Refer to page 37.
Discharge pipe temperature control. Refer to page 39.
Input current control. Refer to page 40.
Freeze-up protection control. Refer to page 41.
Forced Cooling
Operation
Refer to page 97 for details.
Refrigerant circulation rate (high)
high f
low f
freq=variable
Refrigerant circulation rate (low)
high speed
low speed
Amount of heat
exchanged air (large)
Amount of heat
exchanged air (small)
freq=
constant
capacity=
variable
AC
po
w
e
r
DC
po
w
er
Amount of heat
exchanged air (large)
Amount of heat
exchanged air (small)
50 Hz
50 Hz
60 Hz
60 Hz