DAMA-SM-21-001
Troubleshooting
Service Diagnosis
66
Reference
Troubleshooting
Check No.11
Refer to P.88
Check No.11
Check the power supply
waveform.
Check the voltage of the
connection wires on the indoor
terminal strip between No. 1
wire no.3/SIG, and between No. 2
wire no.3/SIG.
YES
Blink
Replace the indoor unit PCB
(control PCB).
Locate and eliminate the
cause of the disturbance of
the power supply waveform.
NO
Continuously ON or OFF
NO
YES
YES
NO
Correct the connection wires
between the indoor unit and
the outdoor unit.
Replace the outdoor unit PCB
(main PCB).
Replace the connection wires
between the indoor unit and
outdoor unit.
Is LED A blinking?
Properly insulated?
Is there any disturbance?
Is there any wiring error?
Check the connection wires
between the indoor unit and the
outdoor unit.
Check the LED A on the outdoor
unit PCB.
NO
YES
Check the power supply voltage.
Correct the power supply.
YES
NO
Replace the outdoor fan motor
and the outdoor unit PCB
(main PCB).
Rotate the
outdoor fan manually.
Does the outdoor fan rotate
smoothly?
Is the
voltage fluctuation
within ±10% from the
rated value?
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Caution
Summary of Contents for FTK Series