SiMT041509E
Specifications
Specifications
4
1. Specifications
50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V
Note:
The data are based on the conditions shown in the table below.
Model
Indoor Unit
FTKM18PVMK
FTKM24PVMK
Outdoor Unit
RKM18PVMK
RKM24PVMK
Capacity
Rated (Min. ~ Max.)
kW
5.28 (1.7 ~ 6.0)
7.03 (1.9 ~ 8.6)
Btu/h
18,000 (5,700 ~ 20,500)
24,000 (6,500 ~ 29,500)
kcal/h
4,540 (1,440 ~ 5,170)
6,050 (1,640 ~ 7,430)
Moisture Removal
L/h
2.9
4.5
Running Current (Rated)
A
6.4 - 6.1 - 5.8 / 6.4 - 6.1
8.8 - 8.4 - 8.1 / 8.8 - 8.4
Power Consumption
Rated (Min. ~ Max.)
W
1,350 (300 ~ 1,700)
1,890 (350 ~ 2,600)
Power Factor (Rated)
%
95.9 - 96.2 - 97.0 / 95.9 - 96.2
97.6 - 97.8 - 97.2 / 97.6 - 97.8
COP
Rated (Min. ~ Max.)
W/W
3.91 (5.57 ~ 3.54)
3.72 (5.46 ~ 3.32)
Piping
Connections
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
12.7
φ
12.7
Drain
mm
—
—
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Max. Interunit Piping Length
m
30
30
Max. Interunit Height Difference
m
20
20
Chargeless
m 10
10
Amount of Additional Charge of
Refrigerant
g/m 20
20
Indoor Unit
FTKM18PVMK
FTKM24PVMK
Front Panel Color (Mancel No.)
White (N95)
White (N95)
Airflow Rate
H
m³/min
(cfm)
20.5 (724)
22.0 (777)
M
16.5 (583)
17.7 (625)
L
12.6 (445)
13.7 (484)
SL
10.9 (385)
12.2 (431)
Fan
Type
Cross Flow Fan
Cross Flow Fan
Motor Output
W
48
48
Speed
Steps
5 Steps, Quiet, Auto
5 Steps, Quiet, Auto
Air Direction Control
Right, Left, Horizontal, Downward
Right, Left, Horizontal, Downward
Air Filter
Removable, Washable, Mildew Proof
Removable, Washable, Mildew Proof
Running Current (Rated)
A
0.45 - 0.43 - 0.41 / 0.45 - 0.43
0.70- 0.67 - 0.64 / 0.70 - 0.67
Power Consumption (Rated)
W
59
85
Power Factor (Rated)
%
59.6 - 59.7 - 60.0 / 59.6 - 59.7
55.2 - 55.2 - 55.3 / 55.2 - 55.2
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H × W × D)
mm
340 × 1,050 × 259
340 × 1,050 × 259
Packaged Dimensions (H × W × D)
mm
342 × 1,160 × 429
342 × 1,160 × 429
Weight (Mass)
kg
15
15
Gross Weight (Gross Mass)
kg
21
21
Sound
Pressure
Level
H / M / L / SL
dB(A)
48 / 42 / 35 / 32
51 / 45 / 37 / 34
Outdoor Unit
RKM18PVMK
RKM24PVMK
Casing Color
Ivory White
Ivory White
Compressor
Type
Hermetically Sealed Swing Type
Hermetically Sealed Swing Type
Model 2YC40BXD
2YC40BXD
Motor Output
W
1,300
1,300
Refrigerant
Oil
Type
FW68DA
FW68DA
Charge
L
0.650 0.650
Refrigerant
Type
R-32
R-32
Charge
kg
1.12 1.40
Airflow Rate
H
m³/min
(cfm)
76.9 (2,715)
74.2 (2,620)
SL
62.0 (2,189)
61.4 (2,168)
Fan
Type
Propeller
Propeller
Motor Output
W
128
128
Running Current (Rated)
A
6.1 - 5.8 - 5.5 / 6.1 - 5.8
8.4 - 8.0 - 7.7 / 8.4 - 8.0
Power Consumption (Rated)
W
1,291
1,805
Power Factor (Rated)
%
96.2 - 96.8 - 97.8 / 96.2 - 96.8
97.7 - 98.1 - 97.7 / 97.7 - 98.1
Starting Current
A
6.4
8.8
Dimensions (H × W × D)
mm
695 × 930 × 350
695 × 930 × 350
Packaged Dimensions (H × W × D)
mm
762 × 1,004 × 475
762 × 1,004 × 475
Weight (Mass)
kg
46
49
Gross Weight (Gross Mass)
kg
52
56
Sound
Pressure
Level
H
dB(A)
51
56
Drawing No.
3D093404
3D093405
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
Cooling
Piping Length
Indoor ; 27°CDB / 19°CWB
Outdoor ; 35°CDB / 24°CWB
7.5 m
Summary of Contents for FTK(X)M-P Series
Page 16: ...SiMT041509E 1 List of Functions Part 1 List of Functions 1 Functions 2...
Page 18: ...SiMT041509E 3 Specifications Part 2 Specifications 1 Specifications 4...
Page 59: ...SiMT041509E Remote Controller 44 Part 5 Remote Controller 1 Remote Controller 45...
Page 118: ...Revision History Month Year Version Revised contents 07 2015 SiMT041509E First edition...