Indoor Unit
SiMT041509E
9
Printed Circuit Board Connector Wiring Diagram
1. Indoor Unit
Control PCB
(PCB1)
Caution
Replace the PCB if you accidentally cut a wrong jumper.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of
them.
Note:
The symbols in the parenthesis are the names on the appropriate wiring diagram.
1) S1
Connector for DC fan motor
2) S21
Connector for centralized control (HA)
3) S25
Connector for INTELLIGENT EYE sensor PCB
4) S32
Indoor heat exchanger thermistor
5) S41
Connector for swing motors
6) S46
Connector for display PCB
7) S47
Connector for signal receiver PCB
8) H1, H2, H3, FG
Connector for terminal board
9) JA
Address setting jumper
∗
Refer to page 94 for detail.
10)JB
Fan speed setting when compressor stops for thermostat OFF
∗
Refer to page 94 for detail.
11)JC
Power failure recovery function (auto-restart)
∗
Refer to page 94 for detail.
12)LED A
LED for service monitor (green)
13)FU1 (F1U),
FU2 (F2U)
Fuse (3.15 A, 250 V)
14)V1
Varistor
2P227881-10
2P227881-11
FU1
V1
H1
H2
FG
H3
LED A
S32
S1
S41
S46
S25
S47
S21
JB
JA
JC
FU2
Summary of Contents for FTK(X)M-P Series
Page 16: ...SiMT041509E 1 List of Functions Part 1 List of Functions 1 Functions 2...
Page 18: ...SiMT041509E 3 Specifications Part 2 Specifications 1 Specifications 4...
Page 59: ...SiMT041509E Remote Controller 44 Part 5 Remote Controller 1 Remote Controller 45...
Page 118: ...Revision History Month Year Version Revised contents 07 2015 SiMT041509E First edition...