For RK25J, RK35J, RX25J, RX35J
SIE-86
118
Removal Procedure
2.8
Removal of Compressor
Procedure
Warning Be sure to turn off all power supplies before disassembling work.
Step
Procedure
Points
1. To Remove the Parts Around
the Compressor.
Be careful so as not to burn the
compressor terminals or the
name plate.
1
Remove the terminal
cover, the lead wires of the
compressor and the
partition plate so as not to
be burnt out by a gas
brazing machine.
2
The compressor’s
mounting nut to be
removed is one piece.
Warning
Since it may happen that
refrigeration oil in the
compressor will catch fire,
prepare wet cloth so as to
extinguish
fire quickly.
Warning!
Ventilate when refrigerant leaks
during the work.( If refrigerant
contacts fire, it will cause to arise
toxic gas).
Caution
Be careful about pipes and so on
, which were heated up by a gas
brazing machine, so as not to get
burnt on your hands.
Pay attention so that the heat
exchanger’s fins will not be
burnt.
3
Remove the nut by means
of an open-end wrench.
Begin your work after
recognizing complete empty
of refrigerant in the
refrigerant circuit.
Be sure to apply nitrogen’s
permutation when heating up
the brazing part.
1
Remove the brazing part
on the compressor
discharge side.
2
Heat up the brazing part
on the compressor suction
part and then remove it.
3
Lift the compressor and
remove it.
Si-86.book Page 118 Friday, June 23, 2000 10:26 AM