General Functionality
SIE-86
18
Main Function
1.6.2
J type
Outline of the
action
It can be commanded for J type by means of a user setting to select either any one desired position among
the five-step directions of air flow adjusted on a remote controller, or Auto-swing.
Although the liquid crystal display of the five-step directions of the air flow is common for the modes of
Cooling·Dry/Heating as illustrated above, in fact the range of the swing angle is slightly different in every
operation mode.
The position a user set will be selected among the five positions calculated through the preliminary and
evenly divided into four partitions which were taken from the upper and lower flap angle’s range limits of
each mode.
When Auto-swing is chosen, the flap swings in the swing range which meets the operation mode selected.
Others
The vertical louver can be adjusted manually. The movable range is 60 degrees for left or right, and
total 120 degrees.
A diffuser is not available for J type.
1
2
3
4
5
Initial
(RL006)
∗
Fan mode is available for the models of cooling-only.
20˚
45˚
Heating mode
0 degree based on
the horizontal line.
(RL007)
0˚
25˚
Cooling /Dry mode
0 degree based on
the horizontal line.
(RL008)
10˚
45˚
0 degree based on
the horizontal line.
Fan mode
(RL009)