SIE-86
General Functionality
Main Function
23
1.10
Intelligent Eye (J type)
Outline
The function that detects existence of humans in the air-conditioned room and reduces the capacity when
no humans are available in the room in order to save electricity by means of a human motion sensor.
Processing
1. Detection method by human motion sensor
This sensor detects human motion by receiving infrared rays and displays the pulse wave output.
A micro computer in an indoor unit carries out a sampling every 20 msec. and if it detects 10 cycles of
the wave in one second in total (corresponding to 20msec.
∞
10 = 100msec.), it judges human is in the
room as the motion signal is ON.
2. The motions (for example: in cooling)
When a micro computer doesn’t have a signal from the sensor in 20 minutes, it judges that no body is in
the room and turns off the human detection LED, operating the unit in temperature sifted 2˚C from the
set temperature. (Cooling : 2˚C higher, Dry: 1˚C higher and Auto : according to the operation mode at
that time.)
1
In case of Fan mode, the fan speed reduces by 50 rpm.
Since the set temperature is shifted by 2˚C higher for 40 minutes, compressor speed becomes low and
can realize energy saving operation. But as thermostat is prone to be off by the fact that the set
temperature has been shifted, the thermostat-off action is prohibited in 40 minutes so as to prevent this
phenomena.
After this 40 minutes, the prohibition of the thermostat-off is cancelled and it can realize the conditions
to conduct thermostat-off depending on the room temperature. In or after this forty minutes, if the
sensor detects human motion detection signal, it turns on “Human detection LED” and let the set
temperature and the fan speed return to the original set point, keeping a normal operation.
If the sensor detects the outputs 10 times/sec.
or more, it judges humans are available.
1sec
sampling (20msec)
High
Low
ON
OFF
Sensor output
(Human motion)
Human detection
signal
(RL019)
ON
OFF
RESET.
C/O Set temp. + 2˚C
H/P Set temp. - 2˚C
Human detection
signal
20 min.
20 min.
within 20
minutes.
40 min.
MaxHz
Mi nHz
0Hz
Compressor
speed
The lower limit by detecting
human.
(Prohibition of thermostat-off)
ON
OFF
ON
OFF
Human motion
detection LED
Remote controller
human motion
detection signal
Sensor button
ON
OFF
Operation
OFF
Fan speed (
1)
34Hz
Set speed - 50 rpm
Set speed
Set speed
in case of
thermostat-off
Frequency at set temp. + 2˚C
Set temp.
(RL020)