SIE-86
Troubleshooting
Service Diagnosis
57
5. Troubleshooting
5.1
Indoor Units
- : Not used for troubleshooting
∗
: Varies depending on the cases.
Indication on the
remote controller
Description of The Fault
Details of fault
(Refer to the
indicated
page.)
000
00000
OR
∗
Indoor unit in normal condition (Conduct a diagnosis of the outdoor unit.)
—
AAA
A1111
Inverter unit - Faulty indoor unit PCB
AAA
A5555
Operation halt due to the freeze protection function or high pressure
control (heat pump model only)
60
AAA
A6666
Faulty fan motor (AC motor stop)
AC motor
61
CCCC4444
Heat exchanger temperature thermistor or related abnormality
62
CCCC999
9
Suction thermistor or related abnormality
62
CCCCAAA
A
Discharge thermistor or related abnormality
62
∗
Faulty indoor unit PCB
63
64
∗
OR
UUU
U4444
Faulty power supply or indoor unit PCB
65
UUU
U4444
Signal transmission error (between indoor and outdoor units)
66
Si-86.book Page 57 Friday, June 23, 2000 10:26 AM