4. Field Settings
4.1 When 2 Units are Installed in 1 Room
Outline
When 2 indoor units are installed in 1 room, 1 of the 2 indoor units and the corresponding
wireless remote controller can be set for different address.
Procedure
1. Remove the battery cover of the remote controller.
2. Cut the address jumper (J4).
3. Press the center of
TEMP
button and
MODE
button on the remote controller at the same
time.
4. Select
A
(address setting) with
TEMP
up or
TEMP
down button.
5. Press
MODE
button to enter the address setting mode.
The indoor unit operation lamp blinks for 1 minute.
6. Press the indoor unit
ON/OFF
switch while the operation lamp is blinking.
7. Press
MODE
button on the remote controller for 5 seconds to return to the normal mode.
Replace the remote controller if you cut a jumper unintentionally
.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of
them.
R7000108
(R24753)
Jumper
(J4)
ADDRESS
J4
EXIST
CUT
1
2
TEMP
bu
tton
MODE
bu
tton
(R24754)
OPERATION
lamp
Indoor unit
ON/OFF