SiMX042215E
Main Functions
Part 4 Functions and Control
35
Note
Note
1.14 Default Set Temperature Setting
Outline
As per BEE regulation, whenever the air conditioner will be switched
ON
from the remote
controller, the default set temperature will be set as follows:
For example,
If switched
OFF
with 20 ˚C set, the unit will be restarted with 24 ˚C cooling mode.
If switched
OFF
with 26 ˚C set, the unit will be restarted with 26 ˚C cooling mode.
In the case of switched
OFF
with dry operation, the unit will be switched
ON
with cooling mode.
To keep dry operation when restarted, select dry operation mode again from the remote
controller.
1.15 Other Functions
1.15.1 Signal Receiving Sign
When the indoor unit receives a signal from the remote controller, the unit emits a signal
receiving sound.
1.15.2 Indoor Unit ON/OFF Switch
Indoor unit
ON/OFF
switch is provided on the display of the unit.
Press
ON/OFF
switch once to start operation. Press once again to stop it.
ON/OFF
switch is useful when the remote controller is missing or the battery has run out.
The operation mode refers to the following table.
R4003873
Forced Cooling Operation
Forced cooling operation can be started by pressing
ON/OFF
switch for 5 ~ 9 seconds while the
unit is not operating.
Refer to page 103 for details.
Forced cooling operation will not be started if the
ON/OFF
switch is pressed for 10 seconds or
more.
1.15.3 Auto-restart Function
If a power failure (even a momentary one) occurs during the operation, the operation restarts
automatically in the same conditions as before when the power supply is restored to the
conditions prior to the power failure.
It takes 3 minutes to restart the operation because 3-minute standby function is activated.
Previously switched
OFF
After switched
ON
again
If set temperature < 24˚C
Set temperature will be 24˚C.
If set temperature >= 24˚C
Set temperature will be kept as previous setting.
If in dry operation
Cooling operation with previously set temperature.
Operation mode
Temperature setting
Airflow rate
COOL
22°C
Automatic
ON/OFF
switch