SiENBE04-401A
Instruction
System Configuration
101
FAULT DIAGNOSIS BY REMOTE CONTROL.
In the ARC433A series, the temperature display sections on the main unit indicate corresponding
codes.
1. When the TIMER CANCEL button is held down for 5 seconds, a “
00
” indication flashes
on the temperature display section.
2. Press the TIMER CANCEL button repeatedly until a continuous beep is produced.
•
The code indication changes as shown below, and notifies with a long beep.
NOTE
CODE
MEANING
SYSTEM
00
NORMAL
U0
REFRIGERANT SHOTAGE
U2
DROP VOLTAGE OR MAIN CIRCUIT OVERVOLTAGE
U4
FAILURE OF TRANSMISSION (BETWEEN INDOOR UNIT AND
OUTDOOR UNIT)
INDOOR UNIT
A1
INDOOR PCB DEFECTIVENESS
A5
HIGH PRESSURE CONTROL OR FREEZE-UP PROTECTOR
A6
FAN MOTOR FAULT
C4
FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
C9
FAULTY SUCTION AIR TEMPERATURE SENSOR
OUTDOOR UNIT
EA
COOLING-HEATING SWITCHING ERROR
E5
OL STARTED
E6
FAULTY COMPRESSOR START UP
E7
DC FAN MOTOR FAULT
E8
OPERATION HALT DUE TO DETECTION OF INPUT OVER CURRENT
F3
HIGH TEMPERATURE DISCHARGE PIPE CONTROL
F6
HIGH PRESSURE CONTROL (IN COOLING)
H6
OPERATION HALT DUE TO FAULTY POSITION DETECTION SENSOR
H8
CT ABNORMALITY
H9
FAULTY SUCTION AIR TEMPERATURE SENSOR
J3
FAULTY DISCHARGE PIPE TEMPERATURE SENSOR
J6
FAULTY HEAT EXCHANGER TEMPERATURE SENSOR
L4
HIGH TEMPERATURE AT INVERTER CIRCUIT HEATSINK
L5
OUTPUT OVERCURRENT
P4
FAULTY INVERTER CIRCUIT HEATSINK TEMPERATURE SENSOR
1. A short beep and two consecutive beeps indicate non-corresponding codes.
2. To cancel the code display, hold the TIMER CANCEL button down for 5 seconds. The code
display also cancel itself if the button is not pressed for 1 minute.
C
O N
TEMP
ON/OFF
POWERFUL
HOME LEAVE
MODE
TIMER
FAN
SWING
SILENT
SENSOR
ON
CANCEL
OFF
TIMER CANCEL button
It cancels the timer setting.
It cancels the timer setting.
TIMER CANCEL button
Summary of Contents for FTKS20CVMB
Page 19: ...List of Functions SiENBE04 401A 10 List of Functions...
Page 45: ...Specifications SiENBE04 401A 36 Specifications...
Page 81: ...Control Specification SiENBE04 401A 72 Function and Control...
Page 111: ...Instruction SiENBE04 401A 102 System Configuration...
Page 155: ...Check SiENBE04 401A 146 Service Diagnosis...
Page 225: ...Outdoor Unit RK X H C ARK X H C R Y N C SiENBE04 401A 216 Removal Procedure...
Page 229: ...Others SiENBE04 401A 220 Others...