Instruction
SiENBE04-401A
82
System Configuration
NOTE
To set the clock
1. Press “CLOCK button”.
0:00
is displayed.
blinks.
2. Press “TIMER setting button” to set the
clock to the present time.
Holding down “
” or “
” button rapidly
increases or decreases the time display.
3. Press “CLOCK button”.
:
blinks.
Turn the breaker ON
•
Turning ON the breaker opens the flap, then
closes it again. (This is a normal procedure.)
Tips for saving energy
•
Be careful not to cool (heat) the room too much.Keeping the temperature setting at a
moderate level helps save energy.
•
Cover windows with a blind or a curtain.Blocking sunlight and air from outdoors
increases the cooling (heating) effect.
•
Clogged air filters cause inefficient operation and waste energy. Clean them once in about every two weeks.
Please note
•
The air conditioner always consumes 15-35 watts of electricity even while it is not operating.
•
If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn the breaker OFF.
•
Use the air conditioner in the following conditions.
•
Operation outside this humidity or temperature range may cause a safety device to disable the system.
C
TEMP
ON/OFF
POWERFUL
HOME LEAVE
MODE
TIMER
FAN
SWING
SILENT
SENSOR
ON
CANCEL
OFF
1.3
2
Recommended temperature setting
For cooling:26°C – 28°C
For heating:20°C – 24°C
Mode
Operating conditions
If operation is continued out of this range
COOL
Outdoor temperature: [2MK(X)S] 10 to 46°C
[3/4MK(X)S] –10 to 46°C
[RK(X)S] –10 to 46°C
[RK(X)H] 10 to 46°C
Indoor temperature: 18 to 32°C
Indoor humidity: 80% max.
• A safety device may work to stop the
operation.(In multi system, it may work to stop
the operation of the outdoor unit only.)
• Condensation may occur on the indoor unit and
drip.
HEAT
Outdoor temperature: [2MXS] –10 to 21°C
[3/4MXS] –15 to 21°C
[RXS] –15 to 21°C
[RXH] –10 to 21°C
Indoor temperature: 10 to 30°C
• A safety device may work to stop the operation.
DRY
Outdoor temperature: [2MK(X)S] 10 to 46°C
[3/4MK(X)S] –10 to 46°C
˛
[RK(X)S] –10 to 46°C
˛
[RK(X)H] 10 to 46°C
Indoor temperature: 18 to 32°C
Indoor humidity: 80% max.
• A safety device may work to stop the operation.
• Condensation may occur on the indoor unit and
drip.
Summary of Contents for FTKS20CVMB
Page 19: ...List of Functions SiENBE04 401A 10 List of Functions...
Page 45: ...Specifications SiENBE04 401A 36 Specifications...
Page 81: ...Control Specification SiENBE04 401A 72 Function and Control...
Page 111: ...Instruction SiENBE04 401A 102 System Configuration...
Page 155: ...Check SiENBE04 401A 146 Service Diagnosis...
Page 225: ...Outdoor Unit RK X H C ARK X H C R Y N C SiENBE04 401A 216 Removal Procedure...
Page 229: ...Others SiENBE04 401A 220 Others...