Flat front panel: its stylish appearance blends easily within any 
interior décor and is more easy to clean.

Lightweight and compact

Consumes up to 30% less energy than non-inverter units

Dual air discharge flow for better air distribution

ECONO mode decreases power consumption so that other 
appliances that need large power supply can be used

Indoor unit On/Off switch

Indoor unit silent operation

Titanium apatite photocatalytic air purification filter

Anticorrosion treatment of outdoor heat exchanger fin

Powerful mode can be selected for rapid cooling or heating

Energy saving during stand by mode: reduction of energy from 10W 
to 2W

optional

5 steps

standard

Summary of Contents for FTX-GV1B

Page 1: ...an non inverter units Dual air discharge flow for better air distribution ECONO mode decreases power consumption so that other appliances that need large power supply can be used Indoor unit On Off sw...

Page 2: ...Fan Type Cross flow fan Quantity 1 1 1 Air Flow Rate Cooling High m min 9 1 9 2 9 3 Medium m min 7 4 7 6 7 7 Low m min 5 9 6 0 6 1 Silent Operation m min 4 7 4 8 4 9 Heating High m min 9 4 9 7 10 1 M...

Page 3: ...irection control Right Left Horizontal Downward Temperature control Microcomputer control Standard Accessories Item Installation manual Quantity 1 1 1 Item Operation manual Quantity 1 1 1 Item Wireles...

Page 4: ...eral rating name plate Model name plate Bottom Signal transmitter Right Flaps Up down Automatic Fan Heating Dry Right left Manual 50Min Space for maintenance 50Min Space for maintenance 30Min Includin...

Page 5: ...Indoor Units R 410A FTX GV1B 1 3 Split Sky Air Indoor Units 5 3 Dimensional drawing centre of gravity 3 2 Centre of gravity FTX20 35GV 4D059099...

Page 6: ...410A FTX GV1B 4 Piping diagram FTX20 35GV 4D058926 Refrigerant flow Heat exchanger Fan motor Cross flow fan Thermistor on heat exch 9 5 Cut INDOOR UNIT Field piping 9 5Cut Field piping 6 4Cut 7 0 Cut...

Page 7: ...r Swing motor Printed circuit board Thermistor Connector Operation switch Terminal strip Protective earth CAUTION Note that operation will restart automaticallyifthemainpower supply is turned off and...

Page 8: ...e band sound pressure level dB 0dB 0 0002 bar Approximate threshold hearing for continuous noise FTX20GV HEATING 1m 0 8m Octave band center frequency Hz 3D058956 NOTES 1 Operating conditons 230V 50Hz...

Page 9: ...band sound pressure level dB 0dB 0 0002 bar Approximate threshold hearing for continuous noise FTX35GV COOLING 1m 0 8m Octave band center frequency Hz 3D058957 NOTES 1 Operating conditons 230V 50Hz 5...