1-14
ELECTRICAL WIRING CONNECTION
Class 09/12
[Method of mounting conduit]
● A protection plate is fixed for protection from the high-voltage section.
1) Dismount the stop valve cover by removing the screw.
2) Dismount the protection plate by removing the 2 screws.
3) Dismount the conduit mounting cover by removing the 2 screws.
4) Pass wires through the conduit and secure them with a lock nut.
5) After completing the work, reattach the stop valve cover, the conduit mounting cover, and the protection plate to its
original position.
SIG
Power supply
terminal block
Protection plate
Screws
Screws
Conduit
Lock nut
Conduit
mounting
cover
Conduit
mounting
cover
Shape wires so
that the proctection
plate and conduit
mounting plate fit
securely.
L1
L2
Class 18/24
[Method of mounting conduit]
1) Dismount the service lid by removing the screws.
2) Pass wires through the conduit and secure them with a lock nut.
3) After completing the work, reattach the service lid to its original position.
L1
L2
Power supply
terminal block
Screws
Conduit
Lock nut
Service lid
Shape wires so
that the proctection
plate and conduit
mounting plate fit
securely.
L1
L2
01_IM-FTX&FTK-DAIKIN_3P601788-2 G-EN.indb 14
01_IM-FTX&FTK-DAIKIN_3P601788-2 G-EN.indb 14
14/10/2022 10:25:04 AM
14/10/2022 10:25:04 AM