8

4.

Wiring.

, install as described in the installation manual supplied with the Multi outdoor unit.

1) Strip wire ends (15mm).
2) Match wire colours with terminal numbers on indoor and outdoor unit’s terminal blocks and firmly screw wires to the corre-

sponding terminals.

3) Connect the earth wires to the corresponding terminals.
4) Pull wires to make sure that they are securely latched up, then retain wires with wire retainer.
5) In case of connecting to an adapter system. Run the remote control cable and attach the S21. (Refer to 5. When connecting to 

an HA system.)

6) Shape the wires so that the service lid fits securely, then close service lid.

WARNING

1) Do not use tapped wires, stranded wires, extension cords, or starburst connections, as they may cause overheating, electrical 

shock, or fire.

2) Do not use locally purchased electrical parts inside the product. (Do not branch the power for the drain pump, etc., from the 

terminal block.) Doing so may cause electric shock or fire.

3) Do not connect the power wire to the indoor unit. Doing so may cause electric shock or fire.

5.

When connecting to an HA system.

1) Remove the front grille. (3 screws)
2) Remove the electrical wiring box. (1 screw)
3) Remove the metal plate electrical wiring cover. (4 tabs)
4) Attach the connection cord to the S21 connector and pull the harness out through the notched part in the figure.
5) Replace the electrical wiring cover as it was,  and pull the harness around, as shown in the figure.

With a Multi indoor unit

Shape wires so 
that the service 
lid will fit securely.

Terminal block

Electrical component box

Wire retainer

Firmly secure wire retainer 
so that wires sustain no 
external stress.

Use the 
specified 
wire type.

1
2
3

1 2 3

L N

When wire length exceeds 
10m, use 2.0mm diameter wires.

H05RN

Firmly fix the wires with 
the terminal screws.

Outdoor unit

Indoor 
unit

Firmly fix the wires with 
the terminal screws.

Screw

HA cord

HA connector
(S21)

Tab

Tab

Push

Slide

Push

Metal plate 
electrical cover

Tab

Push

Main body

Notched part

4)

5) Replace the electrical 

wiring cover as it was,  
and pull the harness 
around, as shown 
in the figure.

Attach the connection cord to 
the S21 connector and pull the 
harness out through the 
notched part in the figure.

3) Remove the metal 

plate electrical 
wiring cover.

01_EN_3P190114-1D.fm  Page 8  Monday, August 23, 2010  3:35 PM

Summary of Contents for FTX50GV1B

Page 1: ...ch Installation manual R410A Split series Installationsanleitung Split Baureihe R410A Manuel d installation Série split R410A Montagehandleiding R410A Split systeem Manual de instalación Serie Split R410A Manuale d installazione Serie Multiambienti R410A Εγχειρßδιο εγκατÜστασηò διαιροýìενηò σειρÜò R410A Manual de Instalação Série split R410A Рóêоводство по монтажó Серия R410A с раздельной óстановê...

Page 2: ...004 108 EC 3SB64526 5F Shinri Sada Manager Quality Control Department 25th of Nov 2009 DAIKIN TCF 015 M18 11 2009 FTKS50FV1B FTKS60FV1B FTKS71FV1B FTXS50FV1B FTXS60FV1B FTXS71FV1B FTX50GV1B FTX60GV1B FTX71GV1B FTYN50FV1B FTYN60FV1B FTN50FV1B FTN60FV1B KEMA Quality B V 74736 KRQ EMC97 4957 3SB64526 5F fm Page 1 Saturday November 28 2009 11 31 AM ...

Page 3: ...amping may cause terminal overheating or fire After connecting interconnecting and supply wiring be sure to shape the cables so that they do not put undue force on the electrical covers or panels Install covers over the wires Incomplete cover installation may cause terminal overheating electrical shock or fire If any refrigerant has leaked out during the installation work ventilate the room The re...

Page 4: ...ated 2 Wireless remote controller 1 Turn on all the fluorescent lamps in the room if any and find the site where remote control signals are properly received by the indoor unit within 7 metres Installation Tips 1 Removing and installing front panel Removal method Hook fingers on the panel protrusions on the left and right of the main body and open until the panel stops Slide the front panel sidewa...

Page 5: ...and firmly engage the upper hooks 3 locations 2 Install 3 screws of the front grille 3 Install the air filter and then mount the front panel 3 How to set the different addresses When two indoor units are installed in one room the two wireless remote con trollers can be set for different addresses 1 In the same way as when connecting to an HA system remove the metal plate electrical wiring cover 2 ...

Page 6: ...mounting plate should be installed on a wall which can support the weight of the indoor unit D E Remote controller holder Wireless remote controller Before screwing the remote controller holder to the wall make sure that control signals are properly received by indoor unit B Titanium Apatite Photocatalytic Air Purifying Filter Tabs upper 3 locations Tabs lower 3 locations Air filters Insert the up...

Page 7: ...rews Recommended mounting plate retention spots and Dimensions 125 60 83 413 5 44 5 290 52 1050 99 5 52 90 55 100 100 Through the wall hole φ80mm Drain hose position φ80 φ80 Recommended mounting plate retention spots 9 spots in all Bolt size M10 Bolt size M10 Place a leveler on raised tab Use tape measure as shown Position the end of tape measure at Gas pipe end Liquid pipe end The removed pipe po...

Page 8: ...t the top of the indoor unit as a guide 4 Open the front panel then open the service lid Refer to Installation tips 5 Pass the interconnecting wires from the outdoor unit through the feed through wall hole and then through the back of the indoor unit Pull them through the front side Bend the ends of tie wires upward in advance for easier work If the interconnecting wire ends are to be stripped fir...

Page 9: ...plate hooks Secure indoor unit to the mounting plate with screws M4 12L 3 3 Wall Embedded Piping Follow the instructions given under 1 Insert the drain hose to this depth so it wont be pulled out of the drain pipe Left Side Left Back or Left Bottom Piping Remove pipe port cover here for left bottom piping Remove pipe port cover here for left side piping Left bottom piping Left side piping Left bac...

Page 10: ...ock or fire 5 When connecting to an HA system 1 Remove the front grille 3 screws 2 Remove the electrical wiring box 1 screw 3 Remove the metal plate electrical wiring cover 4 tabs 4 Attach the connection cord to the S21 connector and pull the harness out through the notched part in the figure 5 Replace the electrical wiring cover as it was and pull the harness around as shown in the figure WithaMu...

Page 11: ...oil from getting into the system as this would reduce the lifetime of the units 3 Never use piping which has been used for previous installations Only use parts which are delivered with the unit 4 Do never install a drier to this R410A unit in order to guarantee its lifetime 5 The drying material may dissolve and damage the system 6 Incomplete flaring may cause refrigerant gas leakage The drain ho...

Page 12: ...and liquid piping and to provide insulation dimen sions as below 3 Use separate thermal insulation pipes for gas and liquid refrigerant pipes Gas side Liquid side Gas pipe thermal insulation Liquid pipe thermal insulation 50 60 class 71 class 50 60 71 class 50 60 class 71 class 50 60 71 class O D 12 7mm O D 15 9mm O D 6 4mm I D 14 16mm I D 16 20mm I D 8 10mm Minimum bend radius Thickness 10mm Min ...

Page 13: ...itioner requires a small amount of power in its standby mode If the system is not to be used for some time after installation shut off the circuit breaker to eliminate unnecessary power consumption If the circuit breaker trips to shut off the power to the air conditioner the system will restore the original operation mode when the circuit breaker is opened again 2 Test items Test Items Symptom dia...

Page 14: ... 1010 HT 3P190114 1D M06B094D Two dimensional bar code is a code for manufacturing 00_CV_3P190114 1D fm Page 2 Monday August 23 2010 3 29 PM ...

Reviews: