2
2
• Split Sky Air • Indoor Units
3
• Indoor Units • R-410A • FTK/XS-DVMW
2
Specifications
2-1 NOMINAL CAPACITY AND POWER INPUT
For indoor units only:
INDOOR UNITS
FTKS20DVMW
FTKS25DVMW
FTKS35DVMW
NOMINAL INPUT
Cooling
kW
0.035
0.035
0.040
For combination outdoor units (air cooled):
COOLING ONLY - INVERTER CONTROLLED (air cooled)
FTKS20DVMW
FTKS25DVMW
FTKS35DVMW
RKS20DVMB
RKS25DVMB
RKS35DVMB
Cooling capacity
min~nom~max kW
1.2~2.0~2.6
1.3~2.5~3.0
1.4~3.4~3.8
Nominal input
min~nom~max kW
0.30~0.49~0.83
0.30~0.685~0.96
0.30~1.045~1.27
EER
4.08
3.65
3.25
Energy label
A
A
A
Annual energy
consumption
Cooling
kWh
245
343
523
2-2 TECHNICAL SPECIFICATIONS
FTKS20DVMW
FTKS25DVMW
FTKS35DVMW
Casing
Colour
White
Dimensions
Packing
Height
mm
340
340
340
Width
mm
855
855
855
Depth
mm
265
265
265
Unit
Height
mm
283
283
283
Width
mm
800
800
800
Depth
mm
195
195
195
Weight
Machine Weight
kg
9.0
9.0
9.0
Gross Weight
kg
12.0
12.0
12.0
Heat Exchanger
Dimensions
Length
mm
610
610
610
Nr of Rows
2
2
2
Fin Pitch
mm
1.40
1.40
1.40
Nr of Stages
12
12
12
Tube type
Hi-XA (7)
Fin
Type
ML fin (Multi louver)
Fan
Type
Cross flow fan
Air Flow Rate
Cooling
High
m
3
/min
8.7
8.7
8.9
Medium
m
3
/min
6.7
6.7
6.9
Low
m
3
/min
4.7
4.7
4.9
Silent
Operation
m
3
/min
3.9
3.9
4.0
Fan
Motor
Quantity
1
1
1
Model
KFD-280-40-8B
Number of steps
5 steps, silent and auto
Motor
Speed (cooling)
High
rpm
1290
1290
1310
Medium
rpm
1050
1050
1070
Low
rpm
810
810
830
Silent
Operation
rpm
710
710
730
Fan
Motor
Output
(high)
W
40
40
40
Cooling
Sound Power
High
dBA
56.0
56.0
57.0
Sound Pressure
High
dBA
38.0
38.0
39.0
Low
dBA
25.0
25.0
26.0
Silent
Operation
dBA
22.0
22.0
23.0
Refrigerant
Type
R-410A