background image

• Indoor Units • R-410A • FTK/XS-DVMW

• Split Sky Air • Indoor Units

4

2

2

Piping 
connections

Liquid (OD)

Diameter 
(OD)

mm

6.35

6.4

6.4

Gas

Diameter 
(OD)

mm

9.5

9.5

9.5

Drain

Diameter 
(OD)

mm

18

18

18

Heat Insulation

Both liquid and gas pipes

Air Filter

Removable/washable/Mildew proof

Air direction control

Left, right, up and downwards

Temperature control

Microcomputer control

Standard 
Accessories

Item

Titanium apatite photocatalytic air purification filter

Quantity

2

2

2

Item

Operation manual

Quantity

1

1

1

Item

Installation manual

Quantity

1

1

1

Item

Infrared remote control

Quantity

1

1

1

Item

Batteries

Quantity

2

2

2

Item

Remote control holder

Quantity

1

1

1

Item

Indoor unit fixing screws

Quantity

2

2

2

Item

Mounting plate

Quantity

1

1

1

2-3 ELECTRICAL SPECIFICATIONS

FTKS20DVMW

FTKS25DVMW

FTKS35DVMW

Power Supply

Name

VM

VM

VM

Phase

1

1

1

Frequency

Hz

50/60

Voltage

V

220-240/220-230

Current

Nominal running 
current (RLA)

Cooling

A

0.16

0.16

0.18

Wiring 
connections

For Power Supply Quantity

3

3

3

Remark

4 for interunit wiring (included earth wiring)

Voltage range

Minimum

-10%

Maximum

+10%

Power Supply Intake

Outdoor unit only

2-4 NOMINAL CAPACITY AND POWER INPUT

For indoor units only:
INDOOR UNITS

FTXS20DVMW

FTXS25DVMW

FTXS35DVMW

NOMINAL INPUT

Cooling

kW

0.035

0.035

0.040

Heating

kW

0.035

0.035

0.040

For combination  outdoor units (air cooled):
COOLING ONLY - INVERTER CONTROLLED (air cooled)

FTXS20DVMW

FTXS25DVMW

FTXS35DVMW

RXS20DVMB

RXS25DVMB

RXS35DVMB

Cooling capacity

min~nom~max kW

1.3~2.0~2.6

1.3~2.5~3.0

1.4~3.4~3.8

Heating capacity

min~nom~max kW

1.3~2.7~4.1

1.3~3.4~4.5

1.4~4.0~5.0

Nominal input

Cooling

min~nom~max kW

0.30~0.49~0.83

0.30~0.685~0.96

0.30~1.045~1.27

Heating

min~nom~max kW

0.29~0.66~1.30

0.29~0.92~1.43

0.31~1.155~1.56

EER

4.08

3.65

3.25

COP

4.09

3.70

3.46

Energy label

Cooling 

A

A

A

Heating

A

A

B

Annual energy 
consumption

Cooling kWh

245

343

523

2-2 TECHNICAL SPECIFICATIONS

FTKS20DVMW

FTKS25DVMW

FTKS35DVMW

Summary of Contents for FTXG-C

Page 1: ...FTXG C Wall Mounted Inverter Controlled Unit technical data Split Sky Air air conditioning systems ...

Page 2: ... the quality of the environment Daikin Europe N V is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard ISO9001 pertains to quality assurance regarding design development manufacturing as well as to services related to the product Daikin units comply with the European regulations that guarantee the safety of the product Daikin Europe N V participates in the ...

Page 3: ...pacity and power input 3 Technical Specifications 3 Electrical Specifications 4 FTXS D Nominal capacity and power input 4 Technical Specifications 5 Electrical Specifications 6 3 Dimensional drawing centre of gravity 7 Dimensional drawing 7 Centre of gravity 8 4 Piping diagram 9 5 Wiring diagram 10 6 Sound data 11 Sound pressure spectrum 11 ...

Page 4: ...y by preventing overcooling or overheating during night time Powerful mode can be selected for rapid cooling Indoor unit silent operation Silent button on the remote control lowers the operation sound of the indoor unit by 3dB A The new titanium apatite photocatalytic air purification filter increases the active surface area for effective purification and deodorisation ECONO mode decreases power c...

Page 5: ...ight mm 340 340 340 Width mm 855 855 855 Depth mm 265 265 265 Unit Height mm 283 283 283 Width mm 800 800 800 Depth mm 195 195 195 Weight Machine Weight kg 9 0 9 0 9 0 Gross Weight kg 12 0 12 0 12 0 Heat Exchanger Dimensions Length mm 610 610 610 Nr of Rows 2 2 2 Fin Pitch mm 1 40 1 40 1 40 Nr of Stages 12 12 12 Tube type Hi XA 7 Fin Type ML fin Multi louver Fan Type Cross flow fan Air Flow Rate C...

Page 6: ...220 240 220 230 Current Nominal running current RLA Cooling A 0 16 0 16 0 18 Wiring connections For Power Supply Quantity 3 3 3 Remark 4 for interunit wiring included earth wiring Voltage range Minimum 10 Maximum 10 Power Supply Intake Outdoor unit only 2 4 NOMINAL CAPACITY AND POWER INPUT For indoor units only INDOOR UNITS FTXS20DVMW FTXS25DVMW FTXS35DVMW NOMINAL INPUT Cooling kW 0 035 0 035 0 04...

Page 7: ...5 0 5 2 Fan Motor Quantity 1 1 1 Model KFD 28040 8B KFD 280 40 8B KFD 280 40 8B Number of steps 5 steps silent and auto Motor Speed cooling High rpm 1290 1290 1310 Medium rpm 1050 1050 1070 Low rpm 810 810 830 Silent Operation rpm 710 710 730 Speed heating High rpm 1320 1320 1360 Medium rpm 1120 1120 1150 Low rpm 920 920 940 Silent Operation rpm 820 820 840 Fan Motor Output high W 40 40 40 Cooling...

Page 8: ...y Name VM VM VM Phase 1 1 1 Frequency Hz 50 60 Voltage V 220 240 220 230 Current Nominal running current RLA Cooling A 0 16 0 16 0 18 Heating A 0 16 0 16 0 18 Wiring connections For Power Supply Quantity 3 3 3 Remark 4 for interunit wiring included earth wiring Voltage range Minimum 10 Maximum 10 Power Supply Intake Outdoor unit only 2 5 TECHNICAL SPECIFICATIONS FTXS20DVMW FTXS25DVMW FTXS35DVMW NO...

Page 9: ... D I S N I R O T S I M R E H T P M E T M O O 2 R O S N E S E Y E T N E G I L L E T N P M A L R E M I 4 P M A L N O I T A R E P H C T I W S F F O N O T I N U R O O D N R E L L O R T N O C E T O M E R S S E L E R I 7 2 L A U N A M T F E L T H G I 2 C I T A M O T U A N W O D P 5 N A E L O H L L A 7 E L O H E S O H N I A R T R A P G N I T C E N N O C S I T I N U E H T E D I S T U O F O H T G N E L E S...

Page 10: ... Indoor Units R 410A FTK XS DVMW Split Sky Air Indoor Units 8 2 3 3 Dimensional drawing centre of gravity 3 2 Centre of gravity FTK XS20 25 35DVMW L 4D048210 ...

Page 11: ...VMW 4 Piping diagram FTK XS20 25 35DVMW L 4D047912 Thermistor on heat exch Cross flow fan Field piping 6 4 CuT Field piping 12 7 CuT Fan motor Refrigerant flow Cooling Heating 9 5 CuT Heat exchanger 6 4 CuT Indoor unit 7 0 CuT Maffler assy 7 9 CuT 6 4 CuT 6 4 CuT ...

Page 12: ...arth FG Frame ground F1U Fuse H1P H3P Pilot lamp L1 Coil M1F Fan motor M1S Swing motor PCB1 PCB4 Printed circuit board R1T R2T Thermistor S1 S38 Connector S1W Operation switch X1M Terminal strip NOTES 1 Size length 70 x width 120 2 Refer to purchasing specification AS303002 unless otherwise specified 3 This drawing was drawn on CAD system 4 Caution Note that operation will restart automatically if...

Page 13: ...ng conditions Power source 230 V 50 Hz o o H A 38 and o o L A 25 4 Operation noise differs with operation and ambient conditions Location of microphone FTKS35DVMW L 4D048245A Approximate threshold hearing for continuous noise Octave band center frequency Octave band sound pressure level 0dB 0 0002μbar NOTES 1 Measurement was taken in an anechoic room 2 The operation noise measuring method is in ac...

Page 14: ...rce 230 V 50 Hz o o H A 39 o o L A 29 4 Operation noise differs with operation and ambient conditions Location of microphone Cooling Heating 1m 0 8m 1m 0 8m FTXS35D 3D048222 Approximate threshold hearing for continuous noise Approximate threshold hearing for continuous noise Octave band center frequency Octave band center frequency Octave band sound pressure level 0dB 0 0002μbar Octave band sound ...

Reviews: