SiBE041012_B
Field Settings
Trial Operation and Field Settings
127
4. Field Settings
4.1
When 2 Units are Installed in 1 Room
Outline
When 2 indoor units are installed in 1 room, 1 of the 2 indoor units and the corresponding
wireless remote controller can be set for different addresses.
Both the indoor unit PCB and the wireless remote controller need alteration.
Indoor Unit PCB
1) Remove the front panel and front grille. (4 screws)
2) Cut the address setting jumper (JA) on the signal receiver / display PCB.
Wireless Remote
Controller
(1) Remove the cover and take it off.
(2) Cut the address setting jumper.
JA
(Bottom of electrical box)
ADDRESS : JA
EXIST : 1
CUT : 2
(R12036)
1
2
EXIST
CUT
Address
Jumper
(R14631)