Functions
SiBE041012_B
4
List of Functions
Category
Functions
FTX
G25/
35JV
1
B
W
(A
)
R
X
G25/
3
5
K
3
V
1
B
FTX
G50J
V
1
BW
(A
)
R
X
G50K
3V
1B
Category
Functions
FTX
G25/
35JV
1
B
W
(A
)
R
X
G25/
3
5
K
3
V
1
B
FTX
G50J
V
1
BW
(A
)
R
X
G50K
3V
1B
Basic Function Inverter (with inverter power control)
z
z
Health & Clean Air-purifying filter
—
—
Operation limit for cooling (°CDB)
10
~ 46
10
~ 46
Photocatalytic deodorizing filter
—
—
Operation limit for heating (°CWB)
–15
~ 18
–15
~18
Air-purifying filter with photocatalytic
deodorizing function
—
—
PAM control
z
z
Titanium apatite photocatalytic
air-purifying filter
z
z
Standby electricity saving
z
—
Compressor
Oval scroll compressor
—
—
Air filter (prefilter)
z
z
Swing compressor
z
z
Wipe-clean flat panel
z
z
Rotary compressor
—
—
Washable grille
—
—
Reluctance DC motor
z
z
MOLD PROOF operation
—
—
Comfortable
Airflow
Power-airflow flap
—
—
Heating dry operation
—
—
Power-airflow dual flaps
z
z
Good-sleep cooling operation
—
—
Power-airflow diffuser
—
—
Timer
WEEKLY TIMER operation
z
z
Wide-angle louvers
z
z
24-hour ON/OFF timer
z
z
Vertical auto-swing (up and down)
z
z
NIGHT SET mode
z
z
Horizontal auto-swing (right and left)
—
—
Worry Free
“Reliability &
Durability”
Auto-restart (after power failure)
z
z
3-D airflow
—
—
Self-diagnosis (digital, LED) display
z
z
COMFORT AIRFLOW operation
z
z
Wiring error check function
—
—
Comfort
Control
Auto fan speed
z
z
Anti-corrosion treatment of outdoor
heat exchanger
z
z
Indoor unit quiet operation
z
z
NIGHT QUIET mode (automatic)
—
—
Flexibility
Multi-split / split type compatible indoor
unit
z
z
OUTDOOR UNIT QUIET operation
(manual)
z
z
INTELLIGENT EYE operation
z
z
Flexible power supply correspondence
—
—
Quick warming function
(preheating operation)
z
z
High ceiling application
—
—
Hot-start function
z
z
Chargeless
10 m 10 m
Automatic defrosting
z
z
Either side drain (right or left)
z
z
Operation
Automatic operation
z
z
Power selection
—
—
Program dry operation
z
z
Remote
Control
5-room centralized controller (option)
z
z
Fan only
z
z
Lifestyle
Convenience
New POWERFUL operation
(non-inverter)
—
—
Remote control adaptor
(normal open pulse contact) (option)
z
z
Inverter POWERFUL operation
z
z
Remote control adaptor
(normal open contact) (option)
z
z
Priority-room setting
—
—
DIII-NET compatible (adaptor) (option)
z
z
COOL / HEAT mode lock
—
—
Remote
Controller
Wireless
z
z
HOME LEAVE operation
—
—
Wired (option)
z
z
ECONO operation
z
z
Indoor unit [ON/OFF] button
z
z
Signal receiving sign
z
z
Multi-colored indicator lamp
(multi-monitor lamp)
z
z
R/C with back light
z
z
Temperature display
—
—
Note:
z
: Holding Functions
— : No Functions
: Lower limit can be extended to –10°C by cutting
jumper. (facility use only)