SiBE041012_B
Outdoor Unit
Printed Circuit Board Connector Wiring Diagram
19
2.2
RXG50K2V1B
Main PCB
Service Monitor
PCB
SW4-A and SW4-B have no function and keep them off.
1) S10
Connector for terminal board (indoor - outdoor transmission)
2) S20
Connector for outdoor electronic expansion valve coil
3) S40
Connector for overload protector
4) S51, S101
Connector for service monitor PCB
5) S70
Connector for fan motor
6) S80
Connector for four way valve coil
7) S90
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
8) AC1, AC2
Connector for terminal board (power supply)
9) E1, E2
Connector for earth wire
10)HR1, HR2
Connector for reactor
11)U, V, W
Connector for compressor
12)FU1
Fuse (30 A, 250 V)
13)FU2, FU3
Fuse (3.15 A, 250 V)
14)V2, V3, V5 V6, V11
Varistor
V3
V11
AC1
FU2
E1
E2
FU3 W
2P282217-1
S40
S20
S80
V U
S70
S90
S51
S10
AC2
S101
V5
V6
V2
FU1
HR1
HR2
1) S52, S102
Connector for main PCB
2) LED A
LED for service monitor (green)
3) SW1
Forced cooling operation [ON/OFF] button
∗
Refer to page 124 for detail.
4) SW4-C
Switch for improvement of defrost performance
∗
Refer to page 130 for detail.
S102
SW1
3P169059-1
LED A
SW4-C
S52